- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Protective Cover:
- with
- Contactor Application:
- resistive load || motor control
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 40 A gG at <= 690 V coordination type 1 for power circuit || 25 A gG at <= 690 V coordination type 2 for power circuit
- Hold-In Power Consumption In Va:
- 7.5-7.5 VA 60 Hz cos phi 0.3 (at 20°C) || 7-7 VA 50 Hz cos phi 0.3 (at 20°C)
- Heat Dissipation:
- 2-3 W 50/60 Hz
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Device Short Name:
- LC2D
- Irms Rated Making Capacity:
- 250 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
- Product Name:
- TeSys D || TeSys Deca
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Coil Technology:
- without built-in suppressor module
- Electrical Durability:
- 2 Mcycles 12 A AC-3 <= 440 V || 0.8 Mcycles 25 A AC-1 <= 440 V || 2 Mcycles 12 A AC-3e <= 440 V
- Utilisation Category:
- AC-1 || AC-3 || AC-3e
- Country of Origin:
- France
- Height:
- 77 mm
- Standards:
- CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Connections - Terminals:
- power circuit screw clamp terminals 1 1-4 mm²flexible without cable end || power circuit screw clamp terminals 2 1-4 mm²flexible without cable end || power circuit screw clamp terminals 1 1-4 mm²flexible with cable end || power circuit screw clamp
- Rated Breaking Capacity:
- 250 A at 440 V for power circuit conforming to IEC 60947
- Control Circuit Voltage Limits:
- 0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Depth:
- 86 mm
- Product Or Component Type:
- reversing contactor
- Interlocking Type:
- mechanical
- Ambient Air Temperature For Operation:
- -40-60°C || 60-70°C with derating
- Toxic Heavy Metal Free:
- Yes
- Environmental Disclosure:
- ENVPEP1501004
- Circularity Profile:
- ENVEOLI1501004
- Overvoltage Category:
- III
- [Icw] Rated Short-Time Withstand Current:
- 30 A 40°C - 10 min for power circuit || 61 A 40°C - 1 min for power circuit || 105 A 40°C - 10 s for power circuit || 210 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms fo
- [Uc] Control Circuit Voltage:
- 48 V AC 50/60 Hz
- Width:
- 90 mm
- Auxiliary Contacts Type:
- mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
- Power Dissipation Per Pole:
- 1.56 W AC-1 || 0.36 W AC-3 || 0.36 W AC-3e
- Motor Power Kw:
- 3 kW at 220...230 V AC 50 Hz || 5.5 kW at 380...400 V AC 50 Hz || 5.5 kW at 415 V AC 50 Hz || 5.5 kW at 440 V AC 50 Hz || 7.5 kW at 500 V AC 50 Hz || 7.5 kW at 660...690 V AC 50 Hz
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Eu Rohs Directive:
- Compliant
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Net Weight:
- 0.697 kg
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
- Signaling Circuit Frequency:
- 25...400 Hz
- Sustainable Offer Status:
- Green Premium product
- [Ui] Rated Insulation Voltage:
- power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
- Pollution Degree:
- 3
- Warranty:
- 18 months