Schneider Electric

Schneider Electric LC2D150Q7 TeSys Deca reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 380 V AC coil

(No reviews yet) Write a Review
SKU:
LC2D150Q7
MPN:
LC2D150Q7
Condition:
New
Width:
266 mm
Rohs Exemption Information:
Yes
Maximum Horse Power Rating:
40 hp at 200/208 V AC 60 Hz for 3 phase motors || 50 hp at 230/240 V AC 60 Hz for 3 phase motors || 100 hp at 460/480 V AC 60 Hz for 3 phase motors || 125 hp at 575/600 V AC 60 Hz for 3 phase motors
Poles Description:
3P
Protective Cover:
with
Pollution Degree:
3
Pvc Free:
Yes
Height:
158 mm
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508
Circularity Profile:
ENVEOLI100405EN
Heat Dissipation:
3-4.5 W 50/60 Hz
Hold-In Power Consumption In Va:
2-18 VA 20°C) 0.9 60 Hz || 2-18 VA 20°C) 0.9 50 Hz
Control Circuit Type:
AC 50/60 Hz
Signaling Circuit Frequency:
25...400 Hz
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 1660 A at 440 V for power circuit conforming to IEC 60947
Coil Technology:
built-in bidirectional peak limiting diode suppressor
Depth:
148 mm
Average Impedance:
0.6 mOhm - Ith 200 A 50 Hz for power circuit
Product Name:
TeSys Deca
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Flame Retardance:
V1 conforming to UL 94
Maximum Operating Rate:
1200 cyc/h 60°C
Pole Contact Composition:
3 NO
Fire Resistance:
850°C IEC 60695-2-1
Rated Breaking Capacity:
1400 A at 440 V for power circuit conforming to IEC 60947
Mercury Free:
Yes
[Ie] Rated Operational Current:
200 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 150 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 150 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Auxiliary Contact Composition:
1 NO + 1 NC
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Device Short Name:
LC2D
Warranty:
18 months
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947
Inrush Power In Va:
280-350 VA 60 Hz 0.9 20°C) || 280-350 VA 50 Hz 0.9 20°C)
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Control Circuit Voltage Limits:
0.3...0.5 Uc 55-55°C drop-out AC 50/60 Hz || 0.8...1.15 Uc 55-55°C operational AC 50/60 Hz
Mechanical Durability:
8000000 cycles
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 315 A gG at <= 690 V coordination type 1 for power circuit || 250 A gG at <= 690 V coordination type 2 for power circuit
Electrical Durability:
0.85 Mcycles 150 A AC-3 <= 440 V || 1 Mcycles 200 A AC-1 <= 440 V || 0.85 Mcycles 150 A AC-3e <= 440 V
Range:
TeSys
Interlocking Type:
mechanical || electrical
Country of Origin:
Czechia
Sustainable Offer Status:
Green Premium product
Operating Time:
20...35 ms closing || 40...75 ms opening
[Uc] Control Circuit Voltage:
380 V AC 50/60 Hz
Overvoltage Category:
III
Net Weight:
6.4 kg
[Ue] Rated Operational Voltage:
power circuit <= 1000 V AC 25...400 Hz || power circuit <= 300 V DC
Device Presentation:
preassembled with reversing power busbar
Weight:
6.4 kg
Eu Rohs Directive:
Compliant with Exemptions
$1,700.00