- Device Short Name:
- LC2D
- Device Presentation:
- preassembled with reversing power busbar
- Operating Time:
- 12...22 ms closing || 4...19 ms opening
- Tightening Torque:
- power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || contro
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Net Weight:
- 0.707 kg
- Flame Retardance:
- V1 conforming to UL 94
- Signaling Circuit Frequency:
- 25...400 Hz
- [Uc] Control Circuit Voltage:
- 24 V AC 50/60 Hz
- Mechanical Durability:
- 15 Mcycles
- Irms Rated Making Capacity:
- 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 300 A at 440 V for power circuit conforming to IEC 60947
- Range:
- TeSys || TeSys Deca
- Toxic Heavy Metal Free:
- Yes
- Poles Description:
- 3P
- Circularity Profile:
- ENVEOLI1501004
- Protective Treatment:
- TH IEC 60068-2-30
- [Icw] Rated Short-Time Withstand Current:
- 40 A 40°C - 10 min for power circuit || 84 A 40°C - 1 min for power circuit || 145 A 40°C - 10 s for power circuit || 240 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms fo
- Warranty:
- 18 months
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Ambient Air Temperature For Operation:
- -40-60°C || 60-70°C with derating
- Coil Technology:
- without built-in suppressor module
- Mercury Free:
- Yes
- Contactor Application:
- resistive load || motor control
- Climatic Withstand:
- IACS E10 || IEC 60947-1 Annex Q category D
- Overvoltage Category:
- III
- Connections - Terminals:
- control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit scr
- Motor Power Kw:
- 4 kW at 220...230 V AC 50 Hz || 7.5 kW at 380...400 V AC 50 Hz || 9 kW at 415...440 V AC 50 Hz || 10 kW at 500 V AC 50 Hz || 10 kW at 660...690 V AC 50 Hz
- Weight:
- 0.707 kg
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Height:
- 77 mm
- Hold-In Power Consumption In Va:
- 7.5-7.5 VA 60 Hz cos phi 0.3 (at 20°C) || 7-7 VA 50 Hz cos phi 0.3 (at 20°C)
- Pole Contact Composition:
- 3 NO
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Control Circuit Type:
- AC 50/60 Hz
- [Ui] Rated Insulation Voltage:
- power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
- Rohs Exemption Information:
- Yes
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Auxiliary Contacts Type:
- mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
- Standards:
- CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Pvc Free:
- Yes
- Country of Origin:
- France
- Rated Breaking Capacity:
- 300 A at 440 V for power circuit conforming to IEC 60947
- Product Name:
- TeSys Deca
- Mechanical Robustness:
- vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor open10 Gn for 11 ms || shocks contactor closed15 Gn for 11 ms
- Mounting Support:
- rail || plate
- Control Circuit Voltage Limits:
- 0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 50 A gG at <= 690 V coordination type 1 for power circuit || 35 A gG at <= 690 V coordination type 2 for power circuit
- Ambient Air Temperature For Storage:
- -60-80°C
- China Rohs Regulation: