Schneider Electric

Schneider Electric LC2D18BD TeSys Deca reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 18 A - 24 V DC coil

(No reviews yet) Write a Review
SKU:
LC2D18BD
MPN:
LC2D18BD
Condition:
New
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Protective Treatment:
TH IEC 60068-2-30
Maximum Horse Power Rating:
1 hp at 115 V AC 60 Hz for 1 phase motors || 3 hp at 230/240 V AC 60 Hz for 1 phase motors || 5 hp at 200/208 V AC 60 Hz for 3 phase motors || 5 hp at 230/240 V AC 60 Hz for 3 phase motors || 10 hp at 460/480 V AC 60 Hz for 3 phase motors || 15 hp at
Product Or Component Type:
reversing contactor
Device Short Name:
LC2D
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
[Uc] Control Circuit Voltage:
24 V DC
Minimum Switching Current:
5 mA for Signaling circuit
Motor Power Kw:
4 kW at 220...230 V AC 50-60 Hz || 7.5 kW at 380...400 V AC 50-60 Hz || 9 kW at 415 V AC 50-60 Hz || 9 kW at 440 V AC 50-60 Hz || 10 kW at 500 V AC 50-60 Hz || 10 kW at 660...690 V AC 50-60 Hz
Power Dissipation Per Pole:
0.8 W AC-3 || 2.5 W AC-1 || 0.8 W AC-3e
Poles Description:
3P
Depth:
95 mm
Maximum Operating Rate:
3600 cyc/h 60°C
Coil Technology:
built-in bidirectional peak limiting diode suppressor
Height:
77 mm
Auxiliary Contact Composition:
1 NO + 1 NC
Fire Resistance:
850°C IEC 60695-2-1
Environmental Disclosure:
ENVPEP110230EN
Mercury Free:
Yes
Ip Degree Of Protection:
IP20 front face IEC 60529
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 50 A gG at <= 690 V coordination type 1 for power circuit || 35 A gG at <= 690 V coordination type 2 for power circuit
Pollution Degree:
3
Control Circuit Voltage Limits:
0.1...0.25 Uc -40-70°C drop-out DC || 0.7...1.25 Uc -40-60°C operational DC || 1...1.25 Uc 60-70°C operational DC
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Product Name:
TeSys D || TeSys Deca
Time Constant:
28 ms
Connections - Terminals:
control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit scr
Ambient Air Temperature For Storage:
-60-80°C
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Overvoltage Category:
III
Sustainable Offer Status:
Green Premium product
Tightening Torque:
power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || contro
Climatic Withstand:
IACS E10 || IEC 60947-1 Annex Q category D
Mechanical Robustness:
vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor open10 Gn for 11 ms || shocks contactor closed15 Gn for 11 ms
Interlocking Type:
mechanical
Signaling Circuit Frequency:
25...400 Hz
Protective Cover:
with
[Icw] Rated Short-Time Withstand Current:
40 A 40°C - 10 min for power circuit || 84 A 40°C - 1 min for power circuit || 145 A 40°C - 10 s for power circuit || 240 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms fo
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 32 A (at 60°C) for power circuit
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 300 A at 440 V for power circuit conforming to IEC 60947
Average Impedance:
2.5 mOhm - Ith 32 A 50 Hz for power circuit
Contactor Application:
motor control || resistive load
Rohs Exemption Information:
Yes
Inrush Power In W:
5.4-5.4 W 20°C)
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
Mechanical Durability:
30 Mcycles
$425.00

Description

LC2D18BD is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications. Rated 18A AC-3 7.5kW@400V, it includes a 24V DC coil, 2NO+2NC aux contacts, a mechanical interlock. LC2D18BD is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications up to 7.5kW@400V. It includes a 24V DC coil and 2NO+2NC built-in auxiliary contacts, NC mirror certified. Compact, DIN-rail mounting, with mechanical interlock and pre-wired reversing circuit, it procures reliability and durability. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Compact product, 90mm wide, for DIN-rail and panel mounting. Assembled with mechanical interlock and pre-wired reversing circuit. Clear separation between power and control circuits, easy front access to coil and auxiliary contacts connections. Equipped with a 24V DC coil for easy integration to all control systems. Provides 4 built-in auxiliary contacts 2NO + 2NC, NC contacts are mirror certified suitable to be included in the control of safety systems. High electrical durability, guaranteed for 2 million cycles at 18A AC-3 440V, for demanding motor switching applications. Robust design with high making and breaking capacities up to 20 In. Connection by screw clamp terminals.
View AllClose