Schneider Electric

Schneider Electric LC2D18E7 TeSys Deca reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 18 A - 48 V AC coil

(No reviews yet) Write a Review
SKU:
LC2D18E7
MPN:
LC2D18E7
Condition:
New
Inrush Power In Va:
70-70 VA 60 Hz cos phi 0.75 (at 20°C) || 70-70 VA 50 Hz cos phi 0.75 (at 20°C)
Pvc Free:
Yes
Range:
TeSys || TeSys Deca
Insulation Resistance:
> 10 MOhm for Signaling circuit
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 32 A (at 60°C) for power circuit
Pole Contact Composition:
3 NO
Rohs Exemption Information:
Yes
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Depth:
86 mm
Signaling Circuit Frequency:
25...400 Hz
Maximum Operating Rate:
3600 cyc/h 60°C
Flame Retardance:
V1 conforming to UL 94
Power Dissipation Per Pole:
0.8 W AC-3 || 2.5 W AC-1 || 0.8 W AC-3e
Overvoltage Category:
III
Contactor Application:
motor control || resistive load
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Product Certifications:
DNV || CSA || CCC || UL || GL || LROS (Lloyds register of shipping) || BV || RINA || GOST || UKCA
Product Name:
TeSys D || TeSys Deca
Protective Cover:
with
Control Circuit Type:
AC 50/60 Hz
Mechanical Durability:
15 Mcycles
Product Or Component Type:
reversing contactor
[Uc] Control Circuit Voltage:
48 V AC 50/60 Hz
Protective Treatment:
TH IEC 60068-2-30
Toxic Heavy Metal Free:
Yes
Electrical Durability:
1.65 Mcycles 18 A AC-3 <= 440 V || 1 Mcycles 32 A AC-1 <= 440 V || 1.65 Mcycles 18 A AC-3e <= 440 V
Operating Time:
12...22 ms closing || 4...19 ms opening
Motor Power Kw:
4 kW at 220...230 V AC 50-60 Hz || 7.5 kW at 380...400 V AC 50-60 Hz || 9 kW at 415 V AC 50-60 Hz || 9 kW at 440 V AC 50-60 Hz || 10 kW at 500 V AC 50-60 Hz || 10 kW at 660...690 V AC 50-60 Hz
Weight:
0.707 kg
Connections - Terminals:
control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit scr
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 50 A gG at <= 690 V coordination type 1 for power circuit || 35 A gG at <= 690 V coordination type 2 for power circuit
Ambient Air Temperature For Operation:
-40-60°C || 60-70°C with derating
Net Weight:
0.707 kg
Rated Breaking Capacity:
300 A at 440 V for power circuit conforming to IEC 60947
Fire Resistance:
850°C IEC 60695-2-1
Utilisation Category:
AC-3 || AC-1 || AC-3e
Mercury Free:
Yes
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 300 A at 440 V for power circuit conforming to IEC 60947
Maximum Horse Power Rating:
1 hp at 115 V AC 60 Hz for 1 phase motors || 3 hp at 230/240 V AC 60 Hz for 1 phase motors || 5 hp at 200/208 V AC 60 Hz for 3 phase motors || 5 hp at 230/240 V AC 60 Hz for 3 phase motors || 10 hp at 460/480 V AC 60 Hz for 3 phase motors || 15 hp at
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
Minimum Switching Current:
5 mA for Signaling circuit
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Interlocking Type:
mechanical
[Icw] Rated Short-Time Withstand Current:
40 A 40°C - 10 min for power circuit || 84 A 40°C - 1 min for power circuit || 145 A 40°C - 10 s for power circuit || 240 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms fo
Device Presentation:
preassembled with reversing power busbar
$416.16

Description

LC2D18E7 is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications. Rated 18A AC-3 7.5kW@400V, it includes a 48V 50/60Hz AC coil, 2NO+2NC aux contacts, a mechanical interlock. LC2D18E7 is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications up to 7.5kW@400V. It includes a 48V 50/60Hz AC coil and 2NO+2NC built-in auxiliary contacts, NC mirror certified. Compact, DIN-rail mounting, with mechanical interlock and pre-wired reversing circuit, it procures reliability and durability. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Compact product, 90mm wide, for DIN-rail and panel mounting. Assembled with mechanical interlock and pre-wired reversing circuit. Clear separation between power and control circuits, easy front access to coil and auxiliary contacts connections. Equipped with a 48V AC coil that can be supplied at 50Hz or 60Hz. Provides 4 built-in auxiliary contacts 2NO + 2NC, NC contacts are mirror certified suitable to be included in the control of safety systems. High electrical durability, guaranteed for 2 million cycles at 18A AC-3 440V, for demanding motor switching applications. Robust design with high making and breaking capacities up to 20 In. Connection by screw clamp terminals.
View AllClose