Schneider Electric

Schneider Electric LC2D25KUE TeSys Deca reversing contactor - 3P - <= 440 V - 25 A AC-3 - 100...250 V AC/DC coil

(No reviews yet) Write a Review
SKU:
LC2D25KUE
MPN:
LC2D25KUE
Condition:
New
Warranty:
18 months
Color:
Gray SE GREY 6) || Green SE GREEN 2)
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || IEC 60335-1
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 40 A (at 60°C) for power circuit
Operating Time:
45...55 ms closing || 20...90 ms opening
Flame Retardance:
V1 conforming to UL 94
Electrical Durability:
2 Mcycles 21 A AC-3 <= 440 V || 0.9 Mcycles 40 A AC-1 <= 440 V
Minimum Switching Voltage:
17 V for Signaling circuit
Mechanical Robustness:
vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor closed15 Gn for 11 ms || shocks contactor open8 Gn for 11 ms
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-1
Device Short Name:
LC2D
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Maximum Operating Rate:
3600 cyc/h 60°C
Minimum Switching Current:
5 mA for Signaling circuit
Mercury Free:
Yes
Depth:
92 mm
Contactor Application:
resistive load || motor control
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 63 A gG at <= 690 V coordination type 1 for power circuit || 40 A gG at <= 690 V coordination type 2 for power circuit
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Poles Description:
3P
Ambient Air Temperature For Storage:
-60-80°C
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Mounting Support:
rail || plate
Weight:
0.913 kg
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz
[Uc] Control Circuit Voltage:
100...250 V AC 50/60 Hz || 100...250 V DC
Circularity Profile:
ENVEOLI1609001EN
Hold-In Power Consumption In W:
1.1-1.1 W 20°C
Fire Resistance:
850°C IEC 60695-2-1
Rohs Exemption Information:
Yes
Heat Dissipation:
1.1-1.1 W 50/60 Hz
Pole Contact Composition:
3 NO
Utilisation Category:
AC-1 || AC-3
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Insulation Resistance:
> 10 MOhm for Signaling circuit
Ip Degree Of Protection:
IP20 front face IEC 60529
Rated Breaking Capacity:
450 A at 440 V for power circuit conforming to IEC 60947
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 450 A at 440 V for power circuit conforming to IEC 60947
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Inrush Power In Va:
25-25 VA 50/60 Hz 20°C)
[Icw] Rated Short-Time Withstand Current:
50 A 40°C - 10 min for power circuit || 120 A 40°C - 1 min for power circuit || 240 A 40°C - 10 s for power circuit || 380 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
Pollution Degree:
3
Interlocking Type:
mechanical
Coil Technology:
built-in bidirectional peak limiting
Maximum Horse Power Rating:
2 hp at 115 V AC 60 Hz for 1 phase motors || 3 hp at 230/240 V AC 60 Hz for 1 phase motors || 7.5 hp at 200/208 V AC 60 Hz for 3 phase motors || 7.5 hp at 230/240 V AC 60 Hz for 3 phase motors || 15 hp at 460/480 V AC 60 Hz for 3 phase motors || 20 h
$186.00

Description

LC2D25KUE is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications. Rated 25A AC-3 11kW@400V, it includes a 100-250V AC/DC low consumption electronic coil, 2NO+2NC aux contacts, a mechanical interlock. LC2D25KUE is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications up to 11kW@400V. It includes a 100-250V AC/DC low consumption electronic coil and 2NO+2NC built-in auxiliary contacts, NC mirror certified. Compact, DIN-rail mounting, with mechanical interlock and pre-wired reversing circuit, it procures reliability and durability. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Compact product, 90mm wide, for DIN-rail and panel mounting. Assembled with mechanical interlock and pre-wired reversing circuit. Clear separation between power and control circuits, easy front access to coil and auxiliary contacts connections. Equipped with an electronic coil, wide band voltage 100-250V, AC/DC compatible, low consumption. Provides 4 built-in auxiliary contacts 2NO + 2NC, NC contacts are mirror certified suitable to be included in the control of safety systems. High electrical durability, guaranteed for 2 million cycles at 25A AC-3 440V, for demanding motor switching applications. Robust design with high making and breaking capacities up to 20 In. Connection by screw clamp terminals.
View AllClose