TeSys D reversing contactor, 3 poles (3NO), for motor control applications up to 32A/690V AC-3 (15kW@400V). It provides 120V 50/60Hz AC coils, 2NO+2NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (90mm width), DIN-rail mounting or screw fixing. With pre-wired reversing power connections, mechanical interlock (without electrical interlocking). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
- Irms Rated Making Capacity:
- 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 550 A at 440 V for power circuit conforming to IEC 60947
- Weight:
- 0.797 kg
- Rohs Exemption Information:
- Yes
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Average Impedance:
- 2 mOhm - Ith 50 A 50 Hz for power circuit
- Pollution Degree:
- 3
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- [Ie] Rated Operational Current:
- 32 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 50 A (at <60°C) at <= 440 V AC AC-1 for power circuit
- [Uc] Control Circuit Voltage:
- 120 V AC 50/60 Hz
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Standards:
- CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
- Eu Rohs Directive:
- Compliant
- Warranty:
- 18 months
- Inrush Power In Va:
- 70-70 VA 60 Hz cos phi 0.75 (at 20°C) || 70-70 VA 50 Hz cos phi 0.75 (at 20°C)
- Fire Resistance:
- 850°C IEC 60695-2-1
- Rated Breaking Capacity:
- 550 A at 440 V for power circuit conforming to IEC 60947
- [Ith] Conventional Free Air Thermal Current:
- 10 A (at 60°C) for Signaling circuit || 50 A (at 60°C) for power circuit
- Climatic Withstand:
- IACS E10 || IEC 60947-1 Annex Q category D
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
- Product Or Component Type:
- reversing contactor
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 63 A gG at <= 690 V coordination type 1 for power circuit || 63 A gG at <= 690 V coordination type 2 for power circuit
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Coil Technology:
- without built-in suppressor module
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Product Name:
- TeSys Deca
- Control Circuit Type:
- AC 50/60 Hz
- Utilisation Category:
- AC-3 || AC-1
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Mounting Support:
- plate || rail
- Maximum Horse Power Rating:
- 2 hp at 115 V AC 60 Hz for 1 phase motors || 5 hp at 230/240 V AC 60 Hz for 1 phase motors || 7.5 hp at 200/208 V AC 60 Hz for 3 phase motors || 10 hp at 230/240 V AC 60 Hz for 3 phase motors || 20 hp at 460/480 V AC 60 Hz for 3 phase motors || 30 hp
- Tightening Torque:
- control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 2.5 N.m screw clamp terminals flat Ø 6 mm || power circuit 2.5 N.m screw clamp terminals Philips No 2 || contro
- Device Short Name:
- LC2D
- Poles Description:
- 3P
- Depth:
- 92 mm
- Circularity Profile:
- ENVEOLI110229EN
- Power Dissipation Per Pole:
- 2 W AC-3 || 5 W AC-1
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Connections - Terminals:
- control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit scr
- Electrical Durability:
- 1.65 Mcycles 32 A AC-3 <= 440 V || 1.4 Mcycles 50 A AC-1 <= 440 V
- Signaling Circuit Frequency:
- 25...400 Hz
- Hold-In Power Consumption In Va:
- 7.5-7.5 VA 60 Hz cos phi 0.3 (at 20°C) || 7-7 VA 50 Hz cos phi 0.3 (at 20°C)
- Protective Cover:
- with
- Minimum Switching Current:
- 5 mA for Signaling circuit
- [Ui] Rated Insulation Voltage:
- power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
- Mechanical Durability:
- 15 Mcycles
- Ambient Air Temperature For Storage:
- -60-80°C
- Interlocking Type:
- electrical and mechanical
- Height:
- 85 mm
- Mechanical Robustness:
- vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor closed15 Gn for 11 ms || shocks contactor open8 Gn for 11 ms
- Overvoltage Category:
- III