Schneider Electric LC2D38KUE TeSys Deca reversing contactor - 3P - <= 440 V - 38 A AC-3 - 100...250 V AC/DC coil
Schneider Electric
$215.00
LC2D38KUE is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications. Rated 38A AC-3 18.5kW@400V, it includes a 100-250V AC/DC low consumption electronic coil, 2NO+2NC aux contacts, a mechanical interlock. LC2D38KUE is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications up to 18.5kW@400V. It includes a 100-250V AC/DC low consumption electronic coil and 2NO+2NC built-in auxiliary contacts, NC mirror certified. Compact, DIN-rail mounting, with mechanical interlock and pre-wired reversing circuit, it procures reliability and durability. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Compact product, 90mm wide, for DIN-rail and panel mounting. Assembled with mechanical interlock and pre-wired reversing circuit. Clear separation between power and control circuits, easy front access to coil and auxiliary contacts connections. Equipped with an electronic coil, wide band voltage 100-250V, AC/DC compatible, low consumption. Provides 4 built-in auxiliary contacts 2NO + 2NC, NC contacts are mirror certified suitable to be included in the control of safety systems. High electrical durability, guaranteed for 2 million cycles at 38A AC-3 440V, for demanding motor switching applications. Robust design with high making and breaking capacities up to 20 In. Connection by screw clamp terminals.
- Inrush Power In Va:
- 25-25 VA 50/60 Hz 20°C)
- Operating Time:
- 45...55 ms closing || 20...90 ms opening
- Ambient Air Temperature For Operation:
- -40-60°C || 60-70°C with derating
- [Uc] Control Circuit Voltage:
- 100...250 V AC 50/60 Hz || 100...250 V DC
- Depth:
- 92 mm
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Device Short Name:
- LC2D
- Contactor Application:
- resistive load || motor control
- [Icw] Rated Short-Time Withstand Current:
- 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms for Signaling circuit || 430 A 40°C - 1 s for power circuit || 60 A 40°C - 10 min for power circuit || 150 A 40°C - 1 min for power circuit || 310 A 40°C - 10
- Control Circuit Voltage Limits:
- <= 0.1 Uc -40-70°C drop-out AC/DC || 0.85...1.1 Uc -40-60°C operational AC/DC || 1...1.1 Uc 60-70°C operational AC/DC
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Hold-In Power Consumption In W:
- 1.1-1.1 W 20°C
- Width:
- 90 mm
- Product Name:
- Tesys Deca green
- Interlocking Type:
- mechanical
- Overvoltage Category:
- III
- Motor Power Kw:
- 9 kW at 220...230 V AC 50 Hz || 18.5 kW at 380...400 V AC 50 Hz || 18.5 kW at 415 V AC 50 Hz || 18.5 kW at 440 V AC 50 Hz || 18.5 kW at 500 V AC 50 Hz || 18.5 kW at 660...690 V AC 50 Hz
- Rohs Exemption Information:
- Yes
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz
- Mounting Support:
- rail || plate
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Protective Cover:
- with
- Rated Breaking Capacity:
- 550 A at 440 V for power circuit conforming to IEC 60947
- Tightening Torque:
- control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 2.5 N.m screw clamp terminals flat Ø 6 mm || power circuit 2.5 N.m screw clamp terminals Philips No 2 || contro
- Heat Dissipation:
- 1.1-1.1 W 50/60 Hz
- Irms Rated Making Capacity:
- 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 550 A at 440 V for power circuit conforming to IEC 60947
- Maximum Horse Power Rating:
- 2 hp at 115 V AC 60 Hz for 1 phase motors || 5 hp at 230/240 V AC 60 Hz for 1 phase motors || 10 hp at 200/208 V AC 60 Hz for 3 phase motors || 10 hp at 230/240 V AC 60 Hz for 3 phase motors || 20 hp at 460/480 V AC 60 Hz for 3 phase motors || 25 hp
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Power Dissipation Per Pole:
- 5 W AC-1 || 3 W AC-3
- Fire Resistance:
- 850°C IEC 60695-2-1
- Color:
- Gray SE GREY 6) || Green SE GREEN 2)
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Inrush Power In W:
- 18-18 W 20°C
- Climatic Withstand:
- IACS E10 || IEC 60947-1 Annex Q category D
- Range:
- TeSys
- Mechanical Robustness:
- vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor closed15 Gn for 11 ms || shocks contactor open8 Gn for 11 ms
- Electrical Durability:
- 1.8 Mcycles 35 A AC-3 <= 440 V || 0.9 Mcycles 50 A AC-1 <= 440 V
- Sustainable Offer Status:
- Green Premium product
- Poles Description:
- 3P
- Eu Rohs Directive:
- Compliant with Exemptions
- Flame Retardance:
- V1 conforming to UL 94
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Country of Origin:
- France
- Warranty:
- 18 months
- Standards:
- EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || IEC 60335-1
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Product Or Component Type:
- reversing contactor
- Net Weight:
- 0.933 kg