- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Eu Rohs Directive:
- Compliant with Exemptions
- Color:
- Gray SE GREY 6) || Green SE GREEN 2)
- Flame Retardance:
- V1 conforming to UL 94
- Standards:
- EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || IEC 60335-1
- Mounting Support:
- rail || plate
- Mechanical Robustness:
- vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor open10 Gn for 11 ms || shocks contactor closed15 Gn for 11 ms
- Electrical Durability:
- 2 Mcycles 35 A AC-3 <= 440 V || 0.7 Mcycles 60 A AC-1 <= 440 V || 2 Mcycles 35 A AC-3e <= 440 V
- Depth:
- 120 mm
- Power Dissipation Per Pole:
- 2.4 W AC-3 || 5.4 W AC-1 || 2.4 W AC-3e
- Control Circuit Type:
- DC DC low consumption
- Device Presentation:
- preassembled with reversing power busbar
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Maximum Horse Power Rating:
- 3 hp at 115 V AC 60 Hz for 1 phase motors || 5 hp at 230/240 V AC 60 Hz for 1 phase motors || 10 hp at 200/208 V AC 60 Hz for 3 phase motors || 10 hp at 230/240 V AC 60 Hz for 3 phase motors || 30 hp at 460/480 V AC 60 Hz for 3 phase motors || 30 hp
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Contactor Application:
- motor control || resistive load
- Irms Rated Making Capacity:
- 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 800 A at 440 V for power circuit conforming to IEC 60947
- Mercury Free:
- Yes
- Product Or Component Type:
- reversing contactor
- Product Certifications:
- CCC || CSA || EAC || UL || KC || DNV-GL || LROS (Lloyds register of shipping) || UKCA
- Protective Treatment:
- TH IEC 60068-2-30
- [Ue] Rated Operational Voltage:
- power circuit 690 V AC 25...400 Hz
- Range:
- TeSys || TeSys Deca
- Control Circuit Voltage Limits:
- <= 0.1 Uc -40-70°C drop-out DC || 0.8...1.2 Uc -40-60°C operational DC || 1...1.2 Uc 60-70°C operational DC
- Ambient Air Temperature For Operation:
- -40-60°C || 60-70°C with derating
- Net Weight:
- 2.154 kg
- [Icw] Rated Short-Time Withstand Current:
- 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms for Signaling circuit || 320 A 40°C - 10 s for power circuit || 720 A 40°C - 1 s for power circuit || 72 A 40°C - 10 min for power circuit || 165 A 40°C - 1 m
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Poles Description:
- 3P
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Weight:
- 2.154 kg
- Connections - Terminals:
- control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit scr
- Ambient Air Temperature For Storage:
- -60-80°C
- Coil Technology:
- built-in bidirectional peak limiting
- Rated Breaking Capacity:
- 800 A at 440 V for power circuit conforming to IEC 60947
- [Uc] Control Circuit Voltage:
- 24 V DC
- Country of Origin:
- United States
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Warranty:
- 18 months
- Fire Resistance:
- 850°C IEC 60695-2-1
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- [Ie] Rated Operational Current:
- 60 A (at <60°C) at <= 440 V AC-1 for power circuit || 40 A (at <60°C) at <= 440 V AC-3 for power circuit || 40 A (at <60°C) at <= 440 V AC-3e for power circuit
- Mechanical Durability:
- 6 Mcycles
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 80 A gG at <= 690 V coordination type 1 for power circuit || 80 A gG at <= 690 V coordination type 2 for power circuit