null

Schneider Electric LC2D40ABNE TeSys Deca reversing contactor - 3P - <= 440 V - 40 A AC-3 - 24...60 V AC/DC coil

Schneider Electric
SKU:
LC2D40ABNE
$311.00
(No reviews yet) Write a Review
Condition:
New
Current Stock:
LC2D40ABNE is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications. Rated 40A AC-3 18.5kW@400V, it includes a 24-60V AC/DC low consumption electronic coil, 2NO+2NC aux contacts, a mechanical interlock. LC2D40ABNE is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications up to 18.5kW@400V. It includes a 24-60V AC/DC low consumption electronic coil and 2NO+2NC built-in auxiliary contacts, NC mirror certified. Compact, DIN-rail mounting, with mechanical interlock and pre-wired reversing circuit, it procures reliability and durability. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Compact product, 119mm wide, for DIN-rail and panel mounting. Assembled with mechanical interlock and pre-wired reversing circuit. Clear separation between power and control circuits, easy front access to coil and auxiliary contacts connections. Equipped with an electronic coil, wide band voltage 24-60V, AC/DC compatible, low consumption. Provides 4 built-in auxiliary contacts 2NO + 2NC, NC contacts are mirror certified suitable to be included in the control of safety systems. High electrical durability, guaranteed for 1.6 million cycles at 40A AC-3 440V, for demanding motor switching applications. Robust design with high making and breaking capacities up to 20 In. Power connections by EverLink BTR screw terminals providing constant tightening pressure.
Control Circuit Voltage Limits:
<= 0.1 Uc -40-70°C drop-out AC/DC || 0.85...1.1 Uc -40-60°C operational AC || 0.8...1.1 Uc -40-60°C operational DC || 1...1.1 Uc 60-70°C operational AC/DC
Mercury Free:
Yes
Interlocking Type:
mechanical
Product Or Component Type:
reversing contactor
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Hold-In Power Consumption In Va:
1-1 VA 20°C) 50/60 Hz
Motor Power Kw:
11 kW at 220...230 V AC 50 Hz || 18.5 kW at 380...400 V AC 50 Hz || 22 kW at 415 V AC 50 Hz || 22 kW at 440 V AC 50 Hz || 22 kW at 500 V AC 50 Hz || 30 kW at 660...690 V AC 50 Hz
Connections - Terminals:
control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit scr
Overvoltage Category:
III
Insulation Resistance:
> 10 MOhm for Signaling circuit
Ambient Air Temperature For Operation:
-40-60°C || 60-70°C with derating
Mechanical Robustness:
vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor open10 Gn for 11 ms || shocks contactor closed15 Gn for 11 ms
Flame Retardance:
V1 conforming to UL 94
Range:
TeSys || TeSys Deca
Power Dissipation Per Pole:
2.4 W AC-3 || 5.4 W AC-1 || 2.4 W AC-3e
Ambient Air Temperature For Storage:
-60-80°C
Inrush Power In W:
16-16 W 20°C
Device Presentation:
preassembled with reversing power busbar
Maximum Horse Power Rating:
3 hp at 115 V AC 60 Hz for 1 phase motors || 5 hp at 230/240 V AC 60 Hz for 1 phase motors || 10 hp at 200/208 V AC 60 Hz for 3 phase motors || 10 hp at 230/240 V AC 60 Hz for 3 phase motors || 30 hp at 460/480 V AC 60 Hz for 3 phase motors || 30 hp
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 800 A at 440 V for power circuit conforming to IEC 60947
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mm || power circuit 5 N.m EverLink BTR screw connecto
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Device Short Name:
LC2D
Warranty:
18 months
[Icw] Rated Short-Time Withstand Current:
100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms for Signaling circuit || 320 A 40°C - 10 s for power circuit || 720 A 40°C - 1 s for power circuit || 72 A 40°C - 10 min for power circuit || 165 A 40°C - 1 m
Product Certifications:
CCC || CSA || EAC || UL || KC || DNV-GL || LROS (Lloyds register of shipping) || UKCA
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 60 A (at 60°C) for power circuit
Climatic Withstand:
IACS E10 || IEC 60947-1 Annex Q category D
Circularity Profile:
ENVEOLI1607010EN
Protective Treatment:
TH IEC 60068-2-30
Rated Breaking Capacity:
800 A at 440 V for power circuit conforming to IEC 60947
Mounting Support:
rail || plate
Ip Degree Of Protection:
IP20 front face IEC 60529
[Ie] Rated Operational Current:
60 A (at <60°C) at <= 440 V AC-1 for power circuit || 40 A (at <60°C) at <= 440 V AC-3 for power circuit || 40 A (at <60°C) at <= 440 V AC-3e for power circuit
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Rohs Exemption Information:
Yes
Utilisation Category:
AC-3 || AC-1 || AC-3e
Pole Contact Composition:
3 NO
Color:
Gray SE GREY 6) || Green SE GREEN 2)
Hold-In Power Consumption In W:
0.7-0.7 W 20°C
Fire Resistance:
850°C IEC 60695-2-1
Control Circuit Type:
AC 50/60 Hz AC/DC electronic || DC AC/DC electronic
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 80 A gG at <= 690 V coordination type 1 for power circuit || 80 A gG at <= 690 V coordination type 2 for power circuit
Height:
122 mm
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Inrush Power In Va:
15-15 VA 50/60 Hz 20°C)
Country of Origin:
France