Schneider Electric LC2D40AM7 TeSys Deca reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 220 V AC coil
Schneider Electric
$667.08
LC2D40AM7 is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications. Rated 40A AC-3 18.5kW@400V, it includes a 220V 50/60Hz AC coil, 2NO+2NC aux contacts, a mechanical interlock. LC2D40AM7 is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications up to 18.5kW@400V. It includes a 220V 50/60Hz AC coil and 2NO+2NC built-in auxiliary contacts, NC mirror certified. Compact, DIN-rail mounting, with mechanical interlock and pre-wired reversing circuit, it procures reliability and durability. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Compact product, 119mm wide, for DIN-rail and panel mounting. Assembled with mechanical interlock and pre-wired reversing circuit. Clear separation between power and control circuits, easy front access to coil and auxiliary contacts connections. Equipped with a 220V AC coil that can be supplied at 50Hz or 60Hz. Provides 4 built-in auxiliary contacts 2NO + 2NC, NC contacts are mirror certified suitable to be included in the control of safety systems. High electrical durability, guaranteed for 1.6 million cycles at 40A AC-3 440V, for demanding motor switching applications. Robust design with high making and breaking capacities up to 20 In. Power connections by EverLink BTR screw terminals providing constant tightening pressure.
- Ambient Air Temperature For Operation:
- -40-60°C || 60-70°C with derating
- Width:
- 119 mm
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Utilisation Category:
- AC-1 || AC-3 || AC-3e
- Flame Retardance:
- V1 conforming to UL 94
- Device Presentation:
- preassembled with reversing power busbar
- Pvc Free:
- Yes
- Protective Treatment:
- TH IEC 60068-2-30
- Maximum Horse Power Rating:
- 5 hp at 230/240 V AC 60 Hz for 1 phase motors || 10 hp at 230/240 V AC 60 Hz for 3 phase motors || 30 hp at 575/600 V AC 60 Hz for 3 phase motors || 10 hp at 200/208 V AC 60 Hz for 3 phase motors || 3 hp at 115 V AC 60 Hz for 1 phase motors || 30 hp
- Heat Dissipation:
- 4-5 W 50/60 Hz
- Ambient Air Temperature For Storage:
- -60-80°C
- Net Weight:
- 1.87 kg
- [Ith] Conventional Free Air Thermal Current:
- 10 A (at 60°C) for Signaling circuit || 60 A (at 60°C) for power circuit
- Mechanical Durability:
- 6 Mcycles
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- [Uc] Control Circuit Voltage:
- 220 V AC 50/60 Hz
- Climatic Withstand:
- IACS E10 || IEC 60947-1 Annex Q category D
- Control Circuit Voltage Limits:
- 0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
- Country of Origin:
- United States
- Electrical Durability:
- 1.5 Mcycles 40 A AC-3 <= 440 V || 1.4 Mcycles 60 A AC-1 <= 440 V || 1.5 Mcycles 40 A AC-3e <= 440 V
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Mercury Free:
- Yes
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Product Or Component Type:
- reversing contactor
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Range:
- TeSys || TeSys Deca
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Eu Rohs Directive:
- Compliant
- Average Impedance:
- 1.5 mOhm - Ith 60 A 50 Hz for power circuit
- Depth:
- 120 mm
- Fire Resistance:
- 850°C IEC 60695-2-1
- Power Dissipation Per Pole:
- 2.4 W AC-3 || 5.4 W AC-1 || 2.4 W AC-3e
- Toxic Heavy Metal Free:
- Yes
- Circularity Profile:
- ENVEOLI1503009EN
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Tightening Torque:
- control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mm || power circuit 5 N.m EverLink BTR screw connecto
- Protective Cover:
- with
- Rohs Exemption Information:
- Yes
- Weight:
- 1.87 kg
- Signaling Circuit Frequency:
- 25...400 Hz
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 80 A gG at <= 690 V coordination type 1 for power circuit || 80 A gG at <= 690 V coordination type 2 for power circuit
- Connections - Terminals:
- control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit scr
- Contactor Application:
- motor control || resistive load
- Overvoltage Category:
- III
- Warranty:
- 18 months
- Inrush Power In Va:
- 140-140 VA 60 Hz cos phi 0.75 (at 20°C) || 160-160 VA 50 Hz cos phi 0.75 (at 20°C)
- Motor Power Kw:
- 11 kW at 220...230 V AC 50-60 Hz || 18.5 kW at 380...400 V AC 50-60 Hz || 22 kW at 415 V AC 50-60 Hz || 22 kW at 440 V AC 50-60 Hz || 22 kW at 500 V AC 50-60 Hz || 30 kW at 660...690 V AC 50-60 Hz
- [Icw] Rated Short-Time Withstand Current:
- 72 A 40°C - 10 min for power circuit || 165 A 40°C - 1 min for power circuit || 320 A 40°C - 10 s for power circuit || 720 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
- Device Short Name:
- LC2D