Schneider Electric LC2D40AV7 TeSys Deca reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 400 V AC coil
Schneider Electric
$667.08
TeSys D reversing contactor, 3 poles (3NO), for motor control applications up to 40A/590V AC-3 (18.5kW@400V). It provides 230V 50/60Hz AC coils, 2NO+2NC built-in auxiliary contacts (NC mirror contacts), power connection by EverLink BTR screw connectors, control by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (119mm width), DIN-rail mounting or screw fixing. With pre-wired reversing power connections, mechanical interlock (without electrical interlocking). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
- Power Dissipation Per Pole:
- 2.4 W AC-3 || 5.4 W AC-1
- Circularity Profile:
- ENVEOLI1503009EN
- Sustainable Offer Status:
- Green Premium product
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Eu Rohs Directive:
- Compliant
- Flame Retardance:
- V1 conforming to UL 94
- Reach Free Of Svhc:
- Yes
- Maximum Horse Power Rating:
- 5 hp at 230/240 V AC 60 Hz for 1 phase motors || 10 hp at 230/240 V AC 60 Hz for 3 phase motors || 30 hp at 575/600 V AC 60 Hz for 3 phase motors || 10 hp at 200/208 V AC 60 Hz for 3 phase motors || 3 hp at 115 V AC 60 Hz for 1 phase motors || 30 hp
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Weight:
- 1.87 kg
- Coil Technology:
- without built-in suppressor module
- Pollution Degree:
- 3
- Inrush Power In Va:
- 140-140 VA 60 Hz cos phi 0.75 (at 20°C) || 160-160 VA 50 Hz cos phi 0.75 (at 20°C)
- Ambient Air Temperature For Operation:
- -40-60°C || 60-70°C with derating
- [Ith] Conventional Free Air Thermal Current:
- 10 A (at 60°C) for Signaling circuit || 60 A (at 60°C) for power circuit
- Electrical Durability:
- 1.5 Mcycles 40 A AC-3 <= 440 V || 1.4 Mcycles 60 A AC-1 <= 440 V
- Control Circuit Type:
- AC 50/60 Hz
- Ambient Air Temperature For Storage:
- -60-80°C
- Mercury Free:
- Yes
- Connections - Terminals:
- control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit scr
- Country of Origin:
- France
- Fire Resistance:
- 850°C IEC 60695-2-1
- [Ie] Rated Operational Current:
- 40 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 60 A (at <60°C) at <= 440 V AC AC-1 for power circuit
- Rohs Exemption Information:
- Yes
- Signaling Circuit Frequency:
- 25...400 Hz
- Hold-In Power Consumption In Va:
- 13-13 VA 60 Hz cos phi 0.3 (at 20°C) || 15-15 VA 50 Hz cos phi 0.3 (at 20°C)
- Warranty:
- 18 months
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Standards:
- CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
- Heat Dissipation:
- 4-5 W 50/60 Hz
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Pvc Free:
- Yes
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Protective Treatment:
- TH IEC 60068-2-30
- Interlocking Type:
- mechanical
- [Icw] Rated Short-Time Withstand Current:
- 72 A 40°C - 10 min for power circuit || 165 A 40°C - 1 min for power circuit || 320 A 40°C - 10 s for power circuit || 720 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Tightening Torque:
- control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mm || power circuit 5 N.m EverLink BTR screw connecto
- Irms Rated Making Capacity:
- 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 800 A at 440 V for power circuit conforming to IEC 60947
- Control Circuit Voltage Limits:
- 0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
- Rated Breaking Capacity:
- 800 A at 440 V for power circuit conforming to IEC 60947
- Net Weight:
- 1.87 kg
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Product Name:
- TeSys D || TeSys Deca
- Operating Time:
- 4...19 ms opening || 12...26 ms closing
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Motor Power Kw:
- 18.5 kW at 380...400 V AC 50 Hz || 11 kW at 220...230 V AC 50 Hz || 22 kW at 415...440 V AC 50 Hz || 22 kW at 500 V AC 50 Hz || 30 kW at 660...690 V AC 50 Hz
- Pole Contact Composition:
- 3 NO