- Poles Description:
- 3P
- Net Weight:
- 1.88 kg
- Width:
- 119 mm
- Reach Free Of Svhc:
- Yes
- Contactor Application:
- resistive load || motor control
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Tightening Torque:
- control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mm || power circuit 5 N.m EverLink BTR screw connecto
- Irms Rated Making Capacity:
- 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 900 A at 440 V for power circuit conforming to IEC 60947
- Toxic Heavy Metal Free:
- Yes
- Protective Cover:
- with
- Control Circuit Voltage Limits:
- 0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
- Pollution Degree:
- 3
- Operating Time:
- 4...19 ms opening || 12...26 ms closing
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Weight:
- 1.88 kg
- Utilisation Category:
- AC-3 || AC-1 || AC-3e
- Ambient Air Temperature For Operation:
- -40-60°C || 60-70°C with derating
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 100 A gG at <= 690 V coordination type 1 for power circuit || 100 A gG at <= 690 V coordination type 2 for power circuit
- Device Presentation:
- preassembled with reversing power busbar
- Device Short Name:
- LC2D
- Coil Technology:
- without built-in suppressor module
- Auxiliary Contacts Type:
- mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
- Country of Origin:
- France
- Connections - Terminals:
- control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit scr
- Sustainable Offer Status:
- Green Premium product
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Mechanical Robustness:
- vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor open10 Gn for 11 ms || shocks contactor closed15 Gn for 11 ms
- Ambient Air Temperature For Storage:
- -60-80°C
- Circularity Profile:
- ENVEOLI1503009EN
- Motor Power Kw:
- 15 kW at 220...230 V AC 50-60 Hz || 22 kW at 380...400 V AC 50-60 Hz || 30 kW at 500 V AC 50-60 Hz || 33 kW at 660...690 V AC 50-60 Hz || 25 kW at 415 V AC 50-60 Hz || 30 kW at 440 V AC 50-60 Hz
- [Icw] Rated Short-Time Withstand Current:
- 400 A 40°C - 10 s for power circuit || 810 A 40°C - 1 s for power circuit || 84 A 40°C - 10 min for power circuit || 208 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
- Signaling Circuit Frequency:
- 25...400 Hz
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
- Depth:
- 120 mm
- Flame Retardance:
- V1 conforming to UL 94
- Standards:
- CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
- Climatic Withstand:
- IACS E10 || IEC 60947-1 Annex Q category D
- Inrush Power In Va:
- 140-140 VA 60 Hz cos phi 0.75 (at 20°C) || 160-160 VA 50 Hz cos phi 0.75 (at 20°C)
- Average Impedance:
- 1.5 mOhm - Ith 80 A 50 Hz for power circuit
- Height:
- 122 mm
- Eu Rohs Directive:
- Compliant
- [Ie] Rated Operational Current:
- 50 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 80 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 50 A (at <60°C) at <= 440 V AC AC-3e for power circuit
- Power Dissipation Per Pole:
- 3.7 W AC-3 || 9.6 W AC-1 || 3.7 W AC-3e
- Rated Breaking Capacity:
- 900 A at 440 V for power circuit conforming to IEC 60947
- Rohs Exemption Information:
- Yes
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Ip Degree Of Protection:
- IP20 front face IEC 60529