Current Stock:
LC2D50ABD is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications. Rated 50A AC-3 22kW@400V, it includes a 24V DC coil, 2NO+2NC aux contacts, a mechanical interlock. LC2D50ABD is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications up to 22kW@400V. It includes a 24V DC coil and 2NO+2NC built-in auxiliary contacts, NC mirror certified. Compact, DIN-rail mounting, with mechanical interlock and pre-wired reversing circuit, it procures reliability and durability. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Compact product, 119mm wide, for DIN-rail and panel mounting. Assembled with mechanical interlock and pre-wired reversing circuit. Clear separation between power and control circuits, easy front access to coil and auxiliary contacts connections. Equipped with a 24V DC coil for easy integration to all control systems. Provides 4 built-in auxiliary contacts 2NO + 2NC, NC contacts are mirror certified suitable to be included in the control of safety systems. High electrical durability, guaranteed for 1.6 million cycles at 50A AC-3 440V, for demanding motor switching applications. Robust design with high making and breaking capacities up to 20 In. Power connections by EverLink BTR screw terminals providing constant tightening pressure.
Auxiliary Contact Composition:
1 NO + 1 NC
Flame Retardance:
V1 conforming to UL 94
Protective Treatment:
TH IEC 60068-2-30
Mechanical Durability:
10 Mcycles
Protective Cover:
with
Average Impedance:
1.5 mOhm - Ith 80 A 50 Hz for power circuit
Country of Origin:
France
Coil Technology:
built-in bidirectional peak limiting diode suppressor
Device Short Name:
LC2D
Time Constant:
34 ms
Ambient Air Temperature For Operation:
-40-60°C || 60-70°C with derating
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
Climatic Withstand:
IACS E10 || IEC 60947-1 Annex Q category D
Inrush Power In W:
19-19 W 20°C)
Fire Resistance:
850°C IEC 60695-2-1
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Motor Power Kw:
15 kW at 220...230 V AC 50-60 Hz || 22 kW at 380...400 V AC 50-60 Hz || 30 kW at 500 V AC 50-60 Hz || 33 kW at 660...690 V AC 50-60 Hz || 25 kW at 415 V AC 50-60 Hz || 30 kW at 440 V AC 50-60 Hz
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Minimum Switching Current:
5 mA for Signaling circuit
Power Dissipation Per Pole:
3.7 W AC-3 || 9.6 W AC-1 || 3.7 W AC-3e
Maximum Operating Rate:
3600 cyc/h 60°C
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mm || power circuit 5 N.m EverLink BTR screw connecto
Rated Breaking Capacity:
900 A at 440 V for power circuit conforming to IEC 60947
Warranty:
18 months
Device Presentation:
preassembled with reversing power busbar
Overvoltage Category:
III
Pollution Degree:
3
Reach Free Of Svhc:
Yes
Range:
TeSys || TeSys Deca
Control Circuit Type:
DC standard
Eu Rohs Directive:
Compliant
Minimum Switching Voltage:
17 V for Signaling circuit
Product Certifications:
UL || CSA || RINA || GOST || CCC || DNV || LROS (Lloyds register of shipping) || GL || BV || UKCA
Electrical Durability:
1.45 Mcycles 50 A AC-3 <= 440 V || 0.5 Mcycles 80 A AC-1 <= 440 V || 1.45 Mcycles 50 A AC-3e <= 440 V
Weight:
2.03 kg
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Control Circuit Voltage Limits:
0.1...0.3 Uc -40-70°C drop-out DC || 0.75...1.25 Uc -40-60°C operational DC || 1...1.25 Uc 60-70°C operational DC
[Icw] Rated Short-Time Withstand Current:
400 A 40°C - 10 s for power circuit || 810 A 40°C - 1 s for power circuit || 84 A 40°C - 10 min for power circuit || 208 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
Interlocking Type:
mechanical
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Mounting Support:
plate || rail
Contactor Application:
motor control || resistive load
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Ambient Air Temperature For Storage:
-60-80°C