- Sustainable Offer Status:
- Green Premium product
- Signaling Circuit Frequency:
- 25...400 Hz
- Mercury Free:
- Yes
- Reach Free Of Svhc:
- Yes
- Protective Treatment:
- TH IEC 60068-2-30
- Product Certifications:
- UL || CSA || RINA || GOST || CCC || DNV || LROS (Lloyds register of shipping) || GL || BV || UKCA
- Maximum Horse Power Rating:
- 3 hp at 115 V AC 60 Hz for 1 phase motors || 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors || 15 hp at 200/208 V AC 60 Hz for 3 phase motors || 15 hp at 230/240 V AC 60 Hz for 3 phase motors || 40 hp at 460/480 V AC 60 Hz for 3 phase motors || 40 h
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Utilisation Category:
- AC-3 || AC-1 || AC-3e
- Irms Rated Making Capacity:
- 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 900 A at 440 V for power circuit conforming to IEC 60947
- Power Dissipation Per Pole:
- 3.7 W AC-3 || 9.6 W AC-1 || 3.7 W AC-3e
- Coil Technology:
- without built-in suppressor module
- Fire Resistance:
- 850°C IEC 60695-2-1
- Contactor Application:
- motor control || resistive load
- Range:
- TeSys || TeSys Deca
- Mounting Support:
- rail || plate
- Connections - Terminals:
- control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit scr
- Overvoltage Category:
- III
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 100 A gG at <= 690 V coordination type 1 for power circuit || 100 A gG at <= 690 V coordination type 2 for power circuit
- Tightening Torque:
- control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mm || power circuit 5 N.m EverLink BTR screw connecto
- Average Impedance:
- 1.5 mOhm - Ith 80 A 50 Hz for power circuit
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Pvc Free:
- Yes
- Control Circuit Type:
- AC 50/60 Hz
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- Product Name:
- TeSys D || TeSys Deca
- Auxiliary Contacts Type:
- mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
- Depth:
- 120 mm
- Interlocking Type:
- mechanical
- Mechanical Durability:
- 6 Mcycles
- Ambient Air Temperature For Storage:
- -60-80°C
- Product Or Component Type:
- reversing contactor
- Climatic Withstand:
- IACS E10 || IEC 60947-1 Annex Q category D
- Eu Rohs Directive:
- Compliant
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Motor Power Kw:
- 15 kW at 220...230 V AC 50-60 Hz || 22 kW at 380...400 V AC 50-60 Hz || 30 kW at 500 V AC 50-60 Hz || 33 kW at 660...690 V AC 50-60 Hz || 25 kW at 415 V AC 50-60 Hz || 30 kW at 440 V AC 50-60 Hz
- Net Weight:
- 1.88 kg
- Rated Breaking Capacity:
- 900 A at 440 V for power circuit conforming to IEC 60947
- Standards:
- CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Flame Retardance:
- V1 conforming to UL 94
- Operating Time:
- 4...19 ms opening || 12...26 ms closing
- [Ith] Conventional Free Air Thermal Current:
- 10 A (at 60°C) for Signaling circuit || 80 A (at 60°C) for power circuit