null

Schneider Electric LC2D50AE7 TeSys Deca reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A - 48 V AC coil

Schneider Electric
SKU:
LC2D50AE7
$752.40
(No reviews yet) Write a Review
Condition:
New
Current Stock:
LC2D50AE7 is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications. Rated 50A AC-3 22kW@400V, it includes a 48V 50/60Hz AC coil, 2NO+2NC aux contacts, a mechanical interlock. LC2D50AE7 is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications up to 22kW@400V. It includes a 48V 50/60Hz AC coil and 2NO+2NC built-in auxiliary contacts, NC mirror certified. Compact, DIN-rail mounting, with mechanical interlock and pre-wired reversing circuit, it procures reliability and durability. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Compact product, 119mm wide, for DIN-rail and panel mounting. Assembled with mechanical interlock and pre-wired reversing circuit. Clear separation between power and control circuits, easy front access to coil and auxiliary contacts connections. Equipped with a 48V AC coil that can be supplied at 50Hz or 60Hz. Provides 4 built-in auxiliary contacts 2NO + 2NC, NC contacts are mirror certified suitable to be included in the control of safety systems. High electrical durability, guaranteed for 1.6 million cycles at 50A AC-3 440V, for demanding motor switching applications. Robust design with high making and breaking capacities up to 20 In. Power connections by EverLink BTR screw terminals providing constant tightening pressure.
Sustainable Offer Status:
Green Premium product
Signaling Circuit Frequency:
25...400 Hz
Mercury Free:
Yes
Reach Free Of Svhc:
Yes
Protective Treatment:
TH IEC 60068-2-30
Product Certifications:
UL || CSA || RINA || GOST || CCC || DNV || LROS (Lloyds register of shipping) || GL || BV || UKCA
Maximum Horse Power Rating:
3 hp at 115 V AC 60 Hz for 1 phase motors || 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors || 15 hp at 200/208 V AC 60 Hz for 3 phase motors || 15 hp at 230/240 V AC 60 Hz for 3 phase motors || 40 hp at 460/480 V AC 60 Hz for 3 phase motors || 40 h
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Utilisation Category:
AC-3 || AC-1 || AC-3e
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 900 A at 440 V for power circuit conforming to IEC 60947
Power Dissipation Per Pole:
3.7 W AC-3 || 9.6 W AC-1 || 3.7 W AC-3e
Coil Technology:
without built-in suppressor module
Fire Resistance:
850°C IEC 60695-2-1
Contactor Application:
motor control || resistive load
Range:
TeSys || TeSys Deca
Mounting Support:
rail || plate
Connections - Terminals:
control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit scr
Overvoltage Category:
III
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 100 A gG at <= 690 V coordination type 1 for power circuit || 100 A gG at <= 690 V coordination type 2 for power circuit
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mm || power circuit 5 N.m EverLink BTR screw connecto
Average Impedance:
1.5 mOhm - Ith 80 A 50 Hz for power circuit
Minimum Switching Current:
5 mA for Signaling circuit
Pvc Free:
Yes
Control Circuit Type:
AC 50/60 Hz
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Product Name:
TeSys D || TeSys Deca
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Depth:
120 mm
Interlocking Type:
mechanical
Mechanical Durability:
6 Mcycles
Ambient Air Temperature For Storage:
-60-80°C
Product Or Component Type:
reversing contactor
Climatic Withstand:
IACS E10 || IEC 60947-1 Annex Q category D
Eu Rohs Directive:
Compliant
Operating Altitude:
0...9842.52 ft (0...3000 m)
Motor Power Kw:
15 kW at 220...230 V AC 50-60 Hz || 22 kW at 380...400 V AC 50-60 Hz || 30 kW at 500 V AC 50-60 Hz || 33 kW at 660...690 V AC 50-60 Hz || 25 kW at 415 V AC 50-60 Hz || 30 kW at 440 V AC 50-60 Hz
Net Weight:
1.88 kg
Rated Breaking Capacity:
900 A at 440 V for power circuit conforming to IEC 60947
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Maximum Operating Rate:
3600 cyc/h 60°C
Flame Retardance:
V1 conforming to UL 94
Operating Time:
4...19 ms opening || 12...26 ms closing
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 80 A (at 60°C) for power circuit