Schneider Electric

Schneider Electric LC2D50AKUE TeSys Deca reversing contactor - 3P - <= 440 V - 50 A AC-3 - 100...250 V AC/DC coil

(No reviews yet) Write a Review
SKU:
LC2D50AKUE
MPN:
LC2D50AKUE
Condition:
New
Climatic Withstand:
IACS E10 || IEC 60947-1 Annex Q category D
Connections - Terminals:
control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit scr
Weight:
2.164 kg
Rohs Exemption Information:
Yes
Product Certifications:
CCC || CSA || EAC || UL || KC || DNV-GL || LROS (Lloyds register of shipping) || UKCA
Poles Description:
3P
Warranty:
18 months
Electrical Durability:
1.8 Mcycles 42 A AC-3 <= 440 V || 0.5 Mcycles 80 A AC-1 <= 440 V
Pollution Degree:
3
Sustainable Offer Status:
Green Premium product
Motor Power Kw:
15 kW at 220...230 V AC 50 Hz || 22 kW at 380...400 V AC 50 Hz || 25 kW at 415 V AC 50 Hz || 30 kW at 440 V AC 50 Hz || 30 kW at 500 V AC 50 Hz || 33 kW at 660...690 V AC 50 Hz
Heat Dissipation:
1.2-1.2 W 50/60 Hz
Eu Rohs Directive:
Compliant with Exemptions
Interlocking Type:
mechanical
Height:
122 mm
Device Presentation:
preassembled with reversing power busbar
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Contactor Application:
resistive load || motor control
Environmental Disclosure:
ENVPEP1607010EN
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
[Uc] Control Circuit Voltage:
100...250 V AC 50/60 Hz || 100...250 V DC
[Icw] Rated Short-Time Withstand Current:
100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms for Signaling circuit || 400 A 40°C - 10 s for power circuit || 810 A 40°C - 1 s for power circuit || 84 A 40°C - 10 min for power circuit || 208 A 40°C - 1 m
Insulation Resistance:
> 10 MOhm for Signaling circuit
Mechanical Robustness:
vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor open10 Gn for 11 ms || shocks contactor closed15 Gn for 11 ms
Device Short Name:
LC2D
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 80 A (at 60°C) for power circuit
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Product Name:
Tesys Deca green || TeSys Deca
Operating Time:
55...65 ms closing || 20...120 ms opening >= 17221) || 20...80 ms opening >= 18011)
Maximum Horse Power Rating:
3 hp at 115 V AC 60 Hz for 1 phase motors || 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors || 15 hp at 200/208 V AC 60 Hz for 3 phase motors || 15 hp at 230/240 V AC 60 Hz for 3 phase motors || 40 hp at 460/480 V AC 60 Hz for 3 phase motors || 40 h
Mechanical Durability:
6 Mcycles
Inrush Power In W:
14-14 W 20°C
Rated Breaking Capacity:
900 A at 440 V for power circuit conforming to IEC 60947
Product Or Component Type:
reversing contactor
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || IEC 60335-1
Ambient Air Temperature For Operation:
-40-60°C || 60-70°C with derating
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mm || power circuit 5 N.m EverLink BTR screw connecto
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 900 A at 440 V for power circuit conforming to IEC 60947
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 100 A gG at <= 690 V coordination type 1 for power circuit || 100 A gG at <= 690 V coordination type 2 for power circuit
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-1
Country of Origin:
France
Circularity Profile:
ENVEOLI1607010EN
Protective Cover:
with
Control Circuit Voltage Limits:
<= 0.1 Uc -40-70°C drop-out AC/DC || 0.85...1.1 Uc -40-60°C operational AC/DC || 1...1.1 Uc 60-70°C operational AC/DC
[Ie] Rated Operational Current:
50 A (at <60°C) at <= 440 V AC-3 for power circuit || 80 A (at <60°C) at <= 440 V AC-1 for power circuit
Signaling Circuit Frequency:
25...400 Hz
Power Dissipation Per Pole:
3.7 W AC-3 || 9.6 W AC-1
Overvoltage Category:
III
$308.00

Description

LC2D50AKUE is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications. Rated 50A AC-3 22kW@400V, it includes a 100-250V AC/DC low consumption electronic coil, 2NO+2NC aux contacts, a mechanical interlock. LC2D50AKUE is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications up to 22kW@400V. It includes a 100-250V AC/DC low consumption electronic coil and 2NO+2NC built-in auxiliary contacts, NC mirror certified. Compact, DIN-rail mounting, with mechanical interlock and pre-wired reversing circuit, it procures reliability and durability. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Compact product, 119mm wide, for DIN-rail and panel mounting. Assembled with mechanical interlock and pre-wired reversing circuit. Clear separation between power and control circuits, easy front access to coil and auxiliary contacts connections. Equipped with an electronic coil, wide band voltage 100-250V, AC/DC compatible, low consumption. Provides 4 built-in auxiliary contacts 2NO + 2NC, NC contacts are mirror certified suitable to be included in the control of safety systems. High electrical durability, guaranteed for 1.6 million cycles at 50A AC-3 440V, for demanding motor switching applications. Robust design with high making and breaking capacities up to 20 In. Power connections by EverLink BTR screw terminals providing constant tightening pressure.
View AllClose