null

Schneider Electric LC2D50AP7 TeSys Deca reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A - 230 V AC coil

Schneider Electric
SKU:
LC2D50AP7
$752.40
(No reviews yet) Write a Review
Condition:
New
Current Stock:
LC2D50AP7 is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications. Rated 50A AC-3 22kW@400V, it includes a 230V 50/60Hz AC coil, 2NO+2NC aux contacts, a mechanical interlock. LC2D50AP7 is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications up to 22kW@400V. It includes a 230V 50/60Hz AC coil and 2NO+2NC built-in auxiliary contacts, NC mirror certified. Compact, DIN-rail mounting, with mechanical interlock and pre-wired reversing circuit, it procures reliability and durability. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Compact product, 119mm wide, for DIN-rail and panel mounting. Assembled with mechanical interlock and pre-wired reversing circuit. Clear separation between power and control circuits, easy front access to coil and auxiliary contacts connections. Equipped with a 230V AC coil that can be supplied at 50Hz or 60Hz. Provides 4 built-in auxiliary contacts 2NO + 2NC, NC contacts are mirror certified suitable to be included in the control of safety systems. High electrical durability, guaranteed for 1.6 million cycles at 50A AC-3 440V, for demanding motor switching applications. Robust design with high making and breaking capacities up to 20 In. Power connections by EverLink BTR screw terminals providing constant tightening pressure.
Sustainable Offer Status:
Green Premium product
Operating Altitude:
0...9842.52 ft (0...3000 m)
Mercury Free:
Yes
Rated Breaking Capacity:
900 A at 440 V for power circuit conforming to IEC 60947
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Control Circuit Type:
AC 50/60 Hz
Mechanical Durability:
6 Mcycles
Flame Retardance:
V1 conforming to UL 94
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Eu Rohs Directive:
Compliant
Operating Time:
4...19 ms opening || 12...26 ms closing
Protective Treatment:
TH IEC 60068-2-30
Motor Power Kw:
15 kW at 220...230 V AC 50-60 Hz || 22 kW at 380...400 V AC 50-60 Hz || 30 kW at 500 V AC 50-60 Hz || 33 kW at 660...690 V AC 50-60 Hz || 25 kW at 415 V AC 50-60 Hz || 30 kW at 440 V AC 50-60 Hz
[Ie] Rated Operational Current:
50 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 80 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 50 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Fire Resistance:
850°C IEC 60695-2-1
Product Name:
TeSys D || TeSys Deca
Mechanical Robustness:
vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor open10 Gn for 11 ms || shocks contactor closed15 Gn for 11 ms
Ip Degree Of Protection:
IP20 front face IEC 60529
Weight:
1.88 kg
Interlocking Type:
mechanical
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 900 A at 440 V for power circuit conforming to IEC 60947
[Uc] Control Circuit Voltage:
230 V AC 50/60 Hz
Range:
TeSys || TeSys Deca
Pole Contact Composition:
3 NO
Maximum Operating Rate:
3600 cyc/h 60°C
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mm || power circuit 5 N.m EverLink BTR screw connecto
Heat Dissipation:
4-5 W 50/60 Hz
Reach Free Of Svhc:
Yes
Rohs Exemption Information:
Yes
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Toxic Heavy Metal Free:
Yes
Protective Cover:
with
Pvc Free:
Yes
Circularity Profile:
ENVEOLI1503009EN
Poles Description:
3P
Environmental Disclosure:
ENVPEP1503009EN
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Device Short Name:
LC2D
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
Signaling Circuit Frequency:
25...400 Hz
Product Certifications:
UL || CSA || RINA || GOST || CCC || DNV || LROS (Lloyds register of shipping) || GL || BV || UKCA
Warranty:
18 months
Device Presentation:
preassembled with reversing power busbar
Average Impedance:
1.5 mOhm - Ith 80 A 50 Hz for power circuit