null

Schneider Electric LC2D65ABBE TeSys Deca reversing contactor - 3P - <= 440 V - 65 A AC-3 - 24 V DC coil

Schneider Electric
SKU:
LC2D65ABBE
$412.00
(No reviews yet) Write a Review
Condition:
New
Current Stock:
LC2D65ABBE is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications. Rated 65A AC-3 30kW@400V, it includes a 24V DC low consumption electronic coil for direct PLC control, 2NO+2NC aux contacts, mechanical interlock. LC2D65ABBE is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications up to 30kW@400V. It includes a 24V DC electronic coil for direct PLC control and 2NO+2NC built-in auxiliary contacts, NC mirror certified. Compact, DIN-rail mounting, with mechanical interlock and pre-wired reversing circuit, it procures reliability and durability. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Compact product, 119mm wide, for DIN-rail and panel mounting. Assembled with mechanical interlock and pre-wired reversing circuit. Clear separation between power and control circuits, easy front access to coil and auxiliary contacts connections. Equipped with an electronic 24V DC coil, low consumption, for a direct control by a PLC output 24V DC / 500mA. Provides 4 built-in auxiliary contacts 2NO + 2NC, NC contacts are mirror certified suitable to be included in the control of safety systems. High electrical durability, guaranteed for 1.6 million cycles at 65A AC-3 440V, for demanding motor switching applications. Robust design with high making and breaking capacities up to 20 In. Power connections by EverLink BTR screw terminals providing constant tightening pressure.
Halogen Content Performance:
Halogen free plastic parts & cables product
Pollution Degree:
3
Maximum Operating Rate:
3600 cyc/h 60°C
Net Weight:
2.174 kg
Electrical Durability:
1.8 Mcycles 57 A AC-3 <= 440 V || 0.5 Mcycles 80 A AC-1 <= 440 V
Product Or Component Type:
reversing contactor
Minimum Switching Voltage:
17 V for Signaling circuit
[Icw] Rated Short-Time Withstand Current:
100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms for Signaling circuit || 520 A 40°C - 10 s for power circuit || 900 A 40°C - 1 s for power circuit || 110 A 40°C - 10 min for power circuit || 260 A 40°C - 1
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Mechanical Robustness:
vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor open10 Gn for 11 ms || shocks contactor closed15 Gn for 11 ms
Overvoltage Category:
III
[Ie] Rated Operational Current:
80 A (at <60°C) at <= 440 V AC-1 for power circuit || 65 A (at <60°C) at <= 440 V AC-3 for power circuit
Connections - Terminals:
control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit scr
Product Name:
Tesys Deca green || TeSys Deca
Device Presentation:
preassembled with reversing power busbar
Inrush Power In W:
11-11 W 20°C
Poles Description:
3P
Range:
TeSys || TeSys Deca
Heat Dissipation:
0.5-0.5 W
Ambient Air Temperature For Operation:
-40-60°C || 60-70°C with derating
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 125 A gG at <= 690 V coordination type 1 for power circuit || 125 A gG at <= 690 V coordination type 2 for power circuit
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
[Ue] Rated Operational Voltage:
power circuit 690 V AC 25...400 Hz
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Height:
122 mm
Device Short Name:
LC2D
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 1000 A at 440 V for power circuit conforming to IEC 60947
Interlocking Type:
mechanical
Environmental Disclosure:
ENVPEP1607010EN
Flame Retardance:
V1 conforming to UL 94
Control Circuit Type:
DC DC low consumption
Average Impedance:
1.5 mOhm - Ith 80 A 50 Hz for power circuit
Signaling Circuit Frequency:
25...400 Hz
Sustainable Offer Status:
Green Premium product
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Fire Resistance:
850°C IEC 60695-2-1
Pole Contact Composition:
3 NO
Rated Breaking Capacity:
1000 A at 440 V for power circuit conforming to IEC 60947
Minimum Switching Current:
5 mA for Signaling circuit
Protective Treatment:
TH IEC 60068-2-30
[Uc] Control Circuit Voltage:
24 V DC
Color:
Gray SE GREY 6) || Green SE GREEN 2)
Mercury Free:
Yes
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Depth:
120 mm
Hold-In Power Consumption In W:
0.5-0.5 W 20°C
Eu Rohs Directive:
Compliant with Exemptions
Control Circuit Voltage Limits:
<= 0.1 Uc -40-70°C drop-out DC || 0.8...1.2 Uc -40-60°C operational DC || 1...1.2 Uc 60-70°C operational DC
Maximum Horse Power Rating:
5 hp at 115 V AC 60 Hz for 1 phase motors || 10 hp at 230/240 V AC 60 Hz for 1 phase motors || 20 hp at 200/208 V AC 60 Hz for 3 phase motors || 20 hp at 230/240 V AC 60 Hz for 3 phase motors || 40 hp at 460/480 V AC 60 Hz for 3 phase motors || 50 hp