Schneider Electric

Schneider Electric LC2D80FE7 TeSys Deca reversing contactor - 3P(3 NO) - AC-3/AC-3e - <= 440 V 80 A - 115 V AC coil

(No reviews yet) Write a Review
SKU:
LC2D80FE7
MPN:
LC2D80FE7
Condition:
New
Toxic Heavy Metal Free:
Yes
Rohs Exemption Information:
Yes
Reach Regulation:
Free of Substances of Very High Concern above the threshold
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Device Short Name:
LC2D
Auxiliary Contact Composition:
1 NO + 1 NC
Signaling Circuit Frequency:
25...400 Hz
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508
Mechanical Durability:
4 Mcycles
Protective Cover:
with
Eu Rohs Directive:
Compliant
Tightening Torque:
control circuit 1.2 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.2 N.m screw clamp terminals Philips No 2 || power circuit 12 N.m connector flat Ø 6 to Ø 8 mm || power circuit 12 N.m connector hexagonal 4 mm || control circuit 1.2 N.
Mounting Support:
rail || plate
Ambient Air Temperature For Operation:
-40-60°C || 60-70°C with derating
Net Weight:
3.2 kg
Power Dissipation Per Pole:
12.5 W AC-1 || 5.1 W AC-3 || 5.1 W AC-3e
Climatic Withstand:
IACS E10
Interlocking Type:
mechanical
Minimum Switching Voltage:
17 V for Signaling circuit
Rated Breaking Capacity:
1100 A at 440 V for power circuit conforming to IEC 60947
Insulation Resistance:
> 10 MOhm for Signaling circuit
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Flame Retardance:
V1 conforming to UL 94
Depth:
158 mm
Motor Power Kw:
22 kW at 220...230 V AC 50 Hz || 37 kW at 380...400 V AC 50 Hz || 45 kW at 415...440 V AC 50 Hz || 55 kW at 500 V AC 50 Hz || 45 kW at 660...690 V AC 50 Hz
Product Name:
TeSys Deca
Connections - Terminals:
control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || control circuit s
Weight:
3.2 kg
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Coil Technology:
without built-in suppressor module
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 1100 A at 440 V for power circuit conforming to IEC 60947
Warranty:
18 months
Fire Resistance:
850°C IEC 60695-2-1
Pvc Free:
Yes
Mechanical Robustness:
vibrations contactor open2 Gn, 5...300 Hz || shocks contactor open8 Gn for 11 ms || vibrations contactor closed3 Gn, 5...300 Hz || shocks contactor closed10 Gn for 11 ms
Device Presentation:
preassembled with reversing power busbar
Electrical Durability:
0.8 Mcycles 125 A AC-1 <= 440 V || 1.5 Mcycles 80 A AC-3 <= 440 V || 1.5 Mcycles 80 A AC-3e <= 440 V
Operating Altitude:
0...9842.52 ft (0...3000 m)
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 125 A (at 60°C) for power circuit
Overvoltage Category:
III
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 1000 V IEC 60947-4-1
Circularity Profile:
N/A
Control Circuit Type:
AC 50/60 Hz
Inrush Power In Va:
245-245 VA 60 Hz cos phi 0.75 (at 20°C) || 245-245 VA 50 Hz cos phi 0.75 (at 20°C)
Minimum Switching Current:
5 mA for Signaling circuit
Ambient Air Temperature For Storage:
-60-80°C
Product Certifications:
UL || CSA || RINA || GOST || CCC || DNV || LROS (Lloyds register of shipping) || GL || BV || UKCA
Pollution Degree:
3
$925.70