Schneider Electric

Schneider Electric LC2DT25E7 TeSys Deca changeover contactor - 4P(4 NO) - AC-1 - <= 440 V 25 A - 48 V AC coil

(No reviews yet) Write a Review
SKU:
LC2DT25E7
MPN:
LC2DT25E7
Condition:
New
Insulation Resistance:
> 10 MOhm for Signaling circuit
Ip Degree Of Protection:
IP20 front face IEC 60529
Toxic Heavy Metal Free:
Yes
Maximum Operating Rate:
3600 cyc/h 60°C
Mercury Free:
Yes
Tightening Torque:
power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || contro
Operating Time:
12...22 ms closing || 4...19 ms opening
Pvc Free:
Yes
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 40 A gG at <= 690 V coordination type 1 for power circuit || 25 A gG at <= 690 V coordination type 2 for power circuit
Protective Cover:
with
Minimum Switching Current:
5 mA for Signaling circuit
Irms Rated Making Capacity:
250 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
Device Presentation:
preassembled, with prewired power connections
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Operating Altitude:
0...9842.52 ft (0...3000 m)
Width:
90 mm
Warranty:
18 months
Product Name:
TeSys D || TeSys Deca
Rated Breaking Capacity:
250 A at 440 V for power circuit conforming to IEC 60947
Net Weight:
0.73 kg
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Ambient Air Temperature For Storage:
-60-80°C
[Icw] Rated Short-Time Withstand Current:
30 A 40°C - 10 min for power circuit || 61 A 40°C - 1 min for power circuit || 105 A 40°C - 10 s for power circuit || 210 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms fo
Fire Resistance:
850°C IEC 60695-2-1
Connections - Terminals:
power circuit screw clamp terminals 1 1-4 mm²flexible without cable end || power circuit screw clamp terminals 2 1-4 mm²flexible without cable end || power circuit screw clamp terminals 1 1-4 mm²flexible with cable end || power circuit screw clamp
Height:
85 mm
Mechanical Durability:
15 Mcycles
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Climatic Withstand:
IACS E10 || IEC 60947-1 Annex Q category D
[Uc] Control Circuit Voltage:
48 V AC 50/60 Hz
Signaling Circuit Frequency:
25...400 Hz
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-60°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz
Contactor Application:
resistive load
Ambient Air Temperature For Operation:
-40-60°C || 60-70°C with derating
Product Or Component Type:
changeover contactor
Mounting Support:
rail || plate
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Inrush Power In Va:
70-70 VA 60 Hz cos phi 0.75 (at 20°C) || 70-70 VA 50 Hz cos phi 0.75 (at 20°C)
Mechanical Robustness:
vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor open10 Gn for 11 ms || shocks contactor closed15 Gn for 11 ms
Electrical Durability:
0.8 Mcycles 25 A AC-1 <= 690 V
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Poles Description:
4P
Pollution Degree:
3
Utilisation Category:
AC-1
Circularity Profile:
ENVEOLI1501004
Eu Rohs Directive:
Compliant
Flame Retardance:
V1 conforming to UL 94
Rohs Exemption Information:
Yes
$420.00

Description

LC2DT25E7 is a Schneider Electric 4-pole (4NO) TeSys D changeover contactor for AC-1 load applications up to 25A/690V. It provides 48V 50/60Hz AC coils, 2NO+2NC built-in auxiliary contacts (NC mirror contacts), power and control connections by screw clamp terminals. Equipped with pre-wired changeover power connections, and mechanical interlock. Compact (90mm width), DIN-rail mounting, it procures high reliability and durability. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). With pre-wired changeover power connections, mechanical interlock (without electrical interlocking). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
View AllClose