Schneider Electric

Schneider Electric LC2DT32G7 TeSys Deca changeover contactor - 4P(4 NO) - AC-1 - <= 440 V 32 A - 120 V AC coil

(No reviews yet) Write a Review
SKU:
LC2DT32G7
MPN:
LC2DT32G7
Condition:
New
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Toxic Heavy Metal Free:
Yes
Auxiliary Contact Composition:
1 NO + 1 NC
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
Operating Time:
12...22 ms closing || 4...19 ms opening
Electrical Durability:
1 Mcycles 32 A AC-1 <= 440 V
Average Impedance:
2.5 mOhm - Ith 32 A 50 Hz for power circuit
Minimum Switching Voltage:
17 V for Signaling circuit
Protective Treatment:
TH IEC 60068-2-30
Country of Origin:
United States
Heat Dissipation:
2-3 W 50/60 Hz
Height:
91 mm
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Protective Cover:
with
Mounting Support:
rail || plate
Pvc Free:
Yes
Connections - Terminals:
control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit scr
Signaling Circuit Frequency:
25...400 Hz
Ambient Air Temperature For Operation:
-40-60°C || 60-70°C with derating
[Uc] Control Circuit Voltage:
120 V AC 50/60 Hz
Environmental Disclosure:
ENVPEP1501004
Hold-In Power Consumption In Va:
7.5-7.5 VA 60 Hz cos phi 0.3 (at 20°C) || 7-7 VA 50 Hz cos phi 0.3 (at 20°C)
Eu Rohs Directive:
Compliant
Utilisation Category:
AC-1 || AC-3 || AC-3e || AC-4
Mechanical Robustness:
vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor closed15 Gn for 11 ms || shocks contactor open8 Gn for 11 ms
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Pole Contact Composition:
4 NO
Contactor Application:
resistive load
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 300 A at 440 V for power circuit conforming to IEC 60947
Width:
90 mm
Net Weight:
0.85 kg
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 50 A gG at <= 690 V coordination type 1 for power circuit || 35 A gG at <= 690 V coordination type 2 for power circuit
Weight:
0.85 kg
Control Circuit Type:
AC 50/60 Hz
Insulation Resistance:
> 10 MOhm for Signaling circuit
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
Power Dissipation Per Pole:
2.5 W AC-1
Mechanical Durability:
15 Mcycles
Rohs Exemption Information:
Yes
Product Certifications:
UL || CSA || RINA || GOST || CCC || DNV || LROS (Lloyds register of shipping) || GL || BV || UKCA || CB
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
Flame Retardance:
V1 conforming to UL 94
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Sustainable Offer Status:
Green Premium product
Depth:
98 mm
Device Presentation:
preassembled, with prewired power connections
[Icw] Rated Short-Time Withstand Current:
40 A 40°C - 10 min for power circuit || 84 A 40°C - 1 min for power circuit || 145 A 40°C - 10 s for power circuit || 240 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms fo
Mercury Free:
Yes
$528.72

Description

TeSys D changeover contactor, 4 poles (4NO), for non-inductive load applications up to 32A/690V AC-1. It provides 230V 50/60Hz AC coils, 2NO+2NC built-in auxiliary contacts (NC mirror contacts), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (90mm width), DIN-rail mounting or screw fixing. With pre-wired changeover power connections, mechanical interlock (without electrical interlocking). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
View AllClose