Schneider Electric LC2DT40F7 REVERSING CONTACTOR 575VAC 40A IEC
Schneider Electric
$601.56
TeSys D reversing contactor, 3 poles (3NO), for motor control applications up to 32A/690V AC-3 (15kW@400V). It provides low consumption 100-250V AC/DC coils with electronic control, 2NO+2NC built-in auxiliary contacts (NC mirror contacts), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (90mm width), DIN-rail mounting or screw fixing. With pre-wired reversing power connections, mechanical interlock (without electrical interlocking). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Connections - Terminals:
- control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit scr
- Power Dissipation Per Pole:
- 3.2 W AC-1
- Signaling Circuit Frequency:
- 25...400 Hz
- Mechanical Robustness:
- vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor closed15 Gn for 11 ms || shocks contactor open8 Gn for 11 ms
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Interlocking Type:
- mechanical
- Contactor Application:
- resistive load
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Pole Contact Composition:
- 4 NO
- Eu Rohs Directive:
- Compliant
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Rohs Exemption Information:
- Yes
- Product Or Component Type:
- changeover contactor
- Pvc Free:
- Yes
- Height:
- 91 mm
- Heat Dissipation:
- 2-3 W 50/60 Hz
- Product Name:
- TeSys Deca
- Mechanical Durability:
- 15 Mcycles
- Flame Retardance:
- V1 conforming to UL 94
- [Ith] Conventional Free Air Thermal Current:
- 10 A (at 60°C) for Signaling circuit || 40 A (at 60°C) for power circuit
- [Uc] Control Circuit Voltage:
- 110 V AC 50/60 Hz
- Product Certifications:
- UL || CSA || CCC || EAC || UKCA || CB || EU-RO-MR by DNV-GL
- Country of Origin:
- France
- Coil Technology:
- without built-in suppressor module
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 63 A gG at <= 690 V coordination type 1 for power circuit || 40 A gG at <= 690 V coordination type 2 for power circuit
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Overvoltage Category:
- III
- Device Presentation:
- preassembled with reversing power busbar
- Net Weight:
- 0.85 kg
- Weight:
- 0.85 kg
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Depth:
- 98 mm
- Ambient Air Temperature For Operation:
- -40-60°C || 60-70°C with derating
- Protective Treatment:
- TH IEC 60068-2-30
- Climatic Withstand:
- IACS E10 || IEC 60947-1 Annex Q category D
- Ambient Air Temperature For Storage:
- -60-80°C
- Fire Resistance:
- 850°C IEC 60695-2-1
- Range:
- TeSys || TeSys Deca
- Mounting Support:
- rail || plate
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- [Ui] Rated Insulation Voltage:
- power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
- Auxiliary Contacts Type:
- mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
- [Ie] Rated Operational Current:
- 40 A (at <60°C) at <= 440 V AC AC-1 for power circuit
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Width:
- 90 mm
- [Icw] Rated Short-Time Withstand Current:
- 50 A 40°C - 10 min for power circuit || 120 A 40°C - 1 min for power circuit || 240 A 40°C - 10 s for power circuit || 380 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
- Irms Rated Making Capacity:
- 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 450 A at 440 V for power circuit conforming to IEC 60947
- Control Circuit Voltage Limits:
- 0.3...0.6 Uc -40-60°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz