[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Maximum Operating Rate:
3600 cyc/h 60°C
Operating Altitude:
0...9842.52 ft (0...3000 m)
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Circularity Profile:
ENVEOLI110229EN
Ambient Air Temperature For Storage:
-60-80°C
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Rated Breaking Capacity:
450 A at 440 V for power circuit conforming to IEC 60947
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 63 A gG at <= 690 V coordination type 1 for power circuit || 40 A gG at <= 690 V coordination type 2 for power circuit
Heat Dissipation:
2-3 W 50/60 Hz
Average Impedance:
2 mOhm - Ith 40 A 50 Hz for power circuit
Eu Rohs Directive:
Compliant
Country of Origin:
France
Height:
91 mm
[Uc] Control Circuit Voltage:
120 V AC 50/60 Hz
Pole Contact Composition:
4 NO
Sustainable Offer Status:
Green Premium product
Depth:
98 mm
Protective Cover:
with
Warranty:
18 months
Flame Retardance:
V1 conforming to UL 94
Fire Resistance:
850°C IEC 60695-2-1
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Ambient Air Temperature For Operation:
-40-60°C || 60-70°C with derating
[Ie] Rated Operational Current:
40 A (at <60°C) at <= 440 V AC AC-1 for power circuit
Range:
TeSys || TeSys Deca
Ip Degree Of Protection:
IP20 front face IEC 60529
Interlocking Type:
mechanical
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Protective Treatment:
TH IEC 60068-2-30
Weight:
0.85 kg
Environmental Disclosure:
ENVPEP110229EN
Power Dissipation Per Pole:
3.2 W AC-1
Hold-In Power Consumption In Va:
7.5-7.5 VA 20°C) 0.3 60 Hz || 7-7 VA 20°C) 0.3 50 Hz
Utilisation Category:
AC-1 || AC-3 || AC-3e || AC-4
Control Circuit Type:
AC 50/60 Hz
Overvoltage Category:
III
Auxiliary Contact Composition:
1 NO + 1 NC
Climatic Withstand:
IACS E10 || IEC 60947-1 Annex Q category D
Product Certifications:
UL || CSA || CCC || EAC || UKCA || CB || EU-RO-MR by DNV-GL
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mounting Support:
rail || plate
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 450 A at 440 V for power circuit conforming to IEC 60947
Net Weight:
0.85 kg
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 1.7 N.m connector flat Ø 6 mm || power circuit 1.7 N.m connector Philips No 2 || power circuit 1.7 N.m screw cl
Contactor Application:
resistive load
[Icw] Rated Short-Time Withstand Current:
50 A 40°C - 10 min for power circuit || 120 A 40°C - 1 min for power circuit || 240 A 40°C - 10 s for power circuit || 380 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
$601.56

Description

TeSys D reversing contactor, 3 poles (3NO), for motor control applications up to 32A/690V AC-3 (15kW@400V). It provides low consumption 100-250V AC/DC coils with electronic control, 2NO+2NC built-in auxiliary contacts (NC mirror contacts), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (90mm width), DIN-rail mounting or screw fixing. With pre-wired reversing power connections, mechanical interlock (without electrical interlocking). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).