Schneider Electric

Schneider Electric LC2DT40GD REVERSING CONTACTOR 575VAC 40A IEC

(No reviews yet) Write a Review
SKU:
LC2DT40GD
MPN:
LC2DT40GD
Condition:
New
Eu Rohs Directive:
Compliant
Environmental Disclosure:
ENVPEP110230EN
Pvc Free:
Yes
Product Name:
TeSys Deca
Minimum Switching Current:
5 mA for Signaling circuit
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 40 A (at 60°C) for power circuit
Pole Contact Composition:
4 NO
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
Climatic Withstand:
IACS E10 || IEC 60947-1 Annex Q category D
Depth:
98 mm
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Poles Description:
4P
Rated Breaking Capacity:
450 A at 440 V for power circuit conforming to IEC 60947
Ip Degree Of Protection:
IP20 front face IEC 60529
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Product Certifications:
UL || CSA || CCC || EAC || UKCA || CB || EU-RO-MR by DNV-GL
Interlocking Type:
mechanical
Width:
90 mm
Product Or Component Type:
changeover contactor
Control Circuit Voltage Limits:
0.1...0.25 Uc -40-60°C drop-out DC || 0.7...1.25 Uc -40-60°C operational DC
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
Circularity Profile:
ENVEOLI1102030EN
Operating Time:
53.55...72.45 ms closing || 16...24 ms opening
Protective Treatment:
TH IEC 60068-2-30
Mechanical Durability:
30 Mcycles
Inrush Power In W:
5.4-5.4 W 20°C
Time Constant:
28 ms
Warranty:
18 months
[Ie] Rated Operational Current:
40 A (at <60°C) at <= 440 V AC AC-1 for power circuit
[Icw] Rated Short-Time Withstand Current:
50 A 40°C - 10 min for power circuit || 120 A 40°C - 1 min for power circuit || 240 A 40°C - 10 s for power circuit || 380 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
Device Presentation:
preassembled with reversing power busbar
Ambient Air Temperature For Storage:
-60-80°C
Connections - Terminals:
control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit scr
Pollution Degree:
3
Mercury Free:
Yes
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Overvoltage Category:
III
Protective Cover:
with
Maximum Operating Rate:
3600 cyc/h 60°C
Signaling Circuit Frequency:
25...400 Hz
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 450 A at 440 V for power circuit conforming to IEC 60947
Mechanical Robustness:
vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor closed15 Gn for 11 ms || shocks contactor open8 Gn for 11 ms
Toxic Heavy Metal Free:
Yes
Control Circuit Type:
DC standard
Average Impedance:
2 mOhm - Ith 40 A 50 Hz for power circuit
Range:
TeSys || TeSys Deca
Insulation Resistance:
> 10 MOhm for Signaling circuit
$601.45

Description

TeSys D reversing contactor, 3 poles (3NO), for motor control applications up to 32A/690V AC-3 (15kW@400V). It provides low consumption 100-250V AC/DC coils with electronic control, 2NO+2NC built-in auxiliary contacts (NC mirror contacts), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (90mm width), DIN-rail mounting or screw fixing. With pre-wired reversing power connections, mechanical interlock (without electrical interlocking). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
View AllClose