Schneider Electric

Schneider Electric LC2DT40P7 TeSys Deca changeover contactor - 4P(4 NO) - AC-1 - <= 440 V 40 A - 230 V AC coil

(No reviews yet) Write a Review
SKU:
LC2DT40P7
MPN:
LC2DT40P7
Condition:
New
Coil Technology:
without built-in suppressor module
Product Name:
TeSys Deca
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 63 A gG at <= 690 V coordination type 1 for power circuit || 40 A gG at <= 690 V coordination type 2 for power circuit
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 40 A (at 60°C) for power circuit
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 450 A at 440 V for power circuit conforming to IEC 60947
Minimum Switching Voltage:
17 V for Signaling circuit
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Protective Cover:
with
Eu Rohs Directive:
Compliant
Mechanical Durability:
15 Mcycles
Ambient Air Temperature For Storage:
-60-80°C
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
[Icw] Rated Short-Time Withstand Current:
50 A 40°C - 10 min for power circuit || 120 A 40°C - 1 min for power circuit || 240 A 40°C - 10 s for power circuit || 380 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Fire Resistance:
850°C IEC 60695-2-1
Inrush Power In Va:
70-70 VA 60 Hz 0.75 20°C) || 70-70 VA 50 Hz 0.75 20°C)
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-60°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz
Operating Altitude:
0...9842.52 ft (0...3000 m)
Country of Origin:
France
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Signaling Circuit Frequency:
25...400 Hz
Ip Degree Of Protection:
IP20 front face IEC 60529
Maximum Operating Rate:
3600 cyc/h 60°C
Circularity Profile:
ENVEOLI110229EN
Depth:
98 mm
Hold-In Power Consumption In Va:
7.5-7.5 VA 20°C) 0.3 60 Hz || 7-7 VA 20°C) 0.3 50 Hz
Width:
90 mm
Control Circuit Type:
AC 50/60 Hz
Climatic Withstand:
IACS E10 || IEC 60947-1 Annex Q category D
Rated Breaking Capacity:
450 A at 440 V for power circuit conforming to IEC 60947
Rohs Exemption Information:
Yes
Mechanical Robustness:
vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor closed15 Gn for 11 ms || shocks contactor open8 Gn for 11 ms
Electrical Durability:
1.4 Mcycles 40 A AC-1 <= 440 V
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Connections - Terminals:
control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit scr
Auxiliary Contact Composition:
1 NO + 1 NC
[Ie] Rated Operational Current:
40 A (at <60°C) at <= 440 V AC AC-1 for power circuit
Environmental Disclosure:
ENVPEP110229EN
Range:
TeSys || TeSys Deca
Interlocking Type:
mechanical
Pole Contact Composition:
4 NO
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 1.7 N.m connector flat Ø 6 mm || power circuit 1.7 N.m connector Philips No 2 || power circuit 1.7 N.m screw cl
Heat Dissipation:
2-3 W 50/60 Hz
Average Impedance:
2 mOhm - Ith 40 A 50 Hz for power circuit
Overvoltage Category:
III
Pollution Degree:
3
Product Or Component Type:
changeover contactor
$601.56

Description

TeSys D changeover contactor, 4 poles (4NO), for non-inductive load applications up to 40A/690V AC-1. It provides 230V 50/60Hz AC coils, 2NO+2NC built-in auxiliary contacts (NC mirror contacts), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (90mm width), DIN-rail mounting or screw fixing. With pre-wired changeover power connections, mechanical interlock (without electrical interlocking). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).