Connections - Terminals:
screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4
[Ith] Conventional Free Air Thermal Current:
20 A (at 60°C) for power circuit || 10 A (at 50°C) for Signaling circuit
Weight:
0.39 kg
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Auxiliary Contact Composition:
1 NC
Product Certifications:
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
Depth:
57 mm
Rohs Exemption Information:
Yes
Inrush Power In Va:
30-30 VA (at 20°C)
Mounting Support:
rail || plate
Utilisation Category:
AC-3 || AC-3e || AC-4
[Uc] Control Circuit Voltage:
24 V AC 50/60 Hz
Circularity Profile:
ENVEOLI1503003EN
Hold-In Power Consumption In Va:
4.5-4.5 VA (at 20°C)
[Ie] Rated Operational Current:
6 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 6 A (at <60°C) at <= 440 V AC AC-3e for power circuit
[Ue] Rated Operational Voltage:
power circuit 690 V AC 50/60 Hz || Signaling circuit <= 690 V AC 50/60 Hz
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Auxiliary Contacts Type:
instantaneous 1 NC
Protective Treatment:
TC IEC 60068 || TC DIN 50016
Device Application:
control
Coil Technology:
built-in bidirectional peak limiting diode suppressor
Warranty:
18 months
Maximum Operating Rate:
3600 cyc/h
Operating Altitude:
6561.68 ft (2000 m) without derating
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Device Presentation:
preassembled with reversing power busbar
Signaling Circuit Frequency:
<= 400 Hz
Non Overlap Distance:
0.5 mm
Associated Fuse Rating:
25 A gG at <= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947 || 10 A gG for Signaling circuit conforming to VDE 0660
Mechanical Robustness:
shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on X axis6 Gn for 11
Tightening Torque:
0.8-1.3 N.m screw clamp terminals Philips No 2 || 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm || 0.8-1.3 N.m screw clamp terminals pozidriv No 2
Standards:
EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1
Minimum Switching Voltage:
17 V for Signaling circuit
Interlocking Type:
mechanical
Rated Breaking Capacity:
110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conformin
Country of Origin:
United States
Ambient Air Temperature For Operation:
-25-50°C
Eu Rohs Directive:
Compliant
Toxic Heavy Metal Free:
Yes
[Ui] Rated Insulation Voltage:
power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-5-1 || Signaling circuit 600 V UL 508 || power circuit 600 V CSA C22.2 No 14 || Signaling circuit 600 V CSA
Ambient Air Temperature For Storage:
-50-80°C
Environmental Disclosure:
ENVPEP1503003EN
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
[Icw] Rated Short-Time Withstand Current:
90 A 50°C - 1 s for power circuit || 85 A 50°C - 5 s for power circuit || 80 A 50°C - 10 s for power circuit || 60 A 50°C - 30 s for power circuit || 45 A 50°C - 1 min for power circuit || 40 A 50°C - 3 min for power circuit || 20 A 50°C - >= 15 min
Electrical Durability:
1.3 Mcycles 6 A AC-3 <= 440 V || 1.3 Mcycles 6 A AC-3e <= 440 V || 0.05 Mcycles 36 A AC-4 <= 440 V
Net Weight:
0.39 kg
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
$150.00

Description

TeSys K reversing contactor, 3 poles (3NO), for motor control applications up to 6A/690V AC-3 (2.2kW@400V). It provides 24V 50/60Hz AC coil with transient suppressor module, 2NC built-in auxiliary contacts, connection by screw clamp terminals. For operating rates until 600 cycles/hour in AC-3 and environments until 50°C, it procures reliability and durability to standard applications. Compact (90mm width), DIN-rail mounting or screw fixing. With pre-wired reversing power connections, mechanical interlock (without electrical interlocking). Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).