- Mounting Support:
- rail || plate
- Associated Fuse Rating:
- 25 A gG at <= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947 || 10 A gG for Signaling circuit conforming to VDE 0660
- Irms Rated Making Capacity:
- 110 A AC for power circuit conforming to IEC 60947 || 110 A AC for Signaling circuit conforming to IEC 60947
- Product Or Component Type:
- reversing contactor
- Device Application:
- control
- Control Circuit Voltage Limits:
- operational: 0.8...1.15 Uc (at <50°C) || drop-out: 0.2...0.75 Uc (at <50°C)
- Sustainable Offer Status:
- Green Premium product
- Interlocking Type:
- mechanical
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- Width:
- 90 mm
- Connections - Terminals:
- screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4
- Auxiliary Contact Composition:
- 1 NC
- Country of Origin:
- France
- Protective Treatment:
- TC IEC 60068 || TC DIN 50016
- Flame Retardance:
- V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
- Weight:
- 0.39 kg
- Device Presentation:
- preassembled with reversing power busbar
- [Ie] Rated Operational Current:
- 6 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 6 A (at <60°C) at <= 440 V AC AC-3e for power circuit
- Maximum Operating Rate:
- 3600 cyc/h
- Overvoltage Category:
- III
- Ambient Air Temperature For Storage:
- -50-80°C
- Product Certifications:
- CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
- Reach Free Of Svhc:
- Yes
- Control Circuit Type:
- AC 50/60 Hz
- Electrical Durability:
- 1.3 Mcycles 6 A AC-3 <= 440 V || 1.3 Mcycles 6 A AC-3e <= 440 V || 0.05 Mcycles 36 A AC-4 <= 440 V
- Poles Description:
- 3P
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV
- [Uc] Control Circuit Voltage:
- 48 V AC 50/60 Hz
- Motor Power Kw:
- 1.5 kW 220...230 V AC 50/60 Hz || 2.2 kW 380...415 V AC 50/60 Hz || 3 kW 440/690 V AC 50/60 Hz
- Rated Breaking Capacity:
- 110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conformin
- Environmental Disclosure:
- ENVPEP1503003EN
- Tightening Torque:
- 0.8-1.3 N.m screw clamp terminals Philips No 2 || 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm || 0.8-1.3 N.m screw clamp terminals pozidriv No 2
- [Ue] Rated Operational Voltage:
- power circuit 690 V AC 50/60 Hz || Signaling circuit <= 690 V AC 50/60 Hz
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Range:
- TeSys
- Average Impedance:
- 3 mOhm - Ith 20 A 50 Hz for power circuit
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Toxic Heavy Metal Free:
- Yes
- Depth:
- 57 mm
- Operating Altitude:
- 6561.68 ft (2000 m) without derating
- Standards:
- EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1
- Net Weight:
- 0.39 kg
- Contactor Application:
- motor control
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Heat Dissipation:
- 1.3-1.3 W
- Product Name:
- TeSys K