Schneider Electric

Schneider Electric LC2K0610B7 Reversing contactor, TeSys K, 3P, AC-3, lt or eq to 440V 6A, 1 NO, 24VAC coil

(No reviews yet) Write a Review
SKU:
LC2K0610B7
MPN:
LC2K0610B7
Condition:
New
Utilisation Category:
AC-3 || AC-3e || AC-4
Irms Rated Making Capacity:
110 A AC for power circuit conforming to IEC 60947 || 110 A AC for Signaling circuit conforming to IEC 60947
Mechanical Durability:
5 Mcycles
Ambient Air Temperature For Storage:
-50-80°C
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Environmental Disclosure:
ENVPEP1503003EN
Auxiliary Contacts Type:
instantaneous 1 NO
Interlocking Type:
mechanical
Minimum Switching Voltage:
17 V for Signaling circuit
Operating Altitude:
6561.68 ft (2000 m) without derating
Overvoltage Category:
III
Insulation Resistance:
> 10 MOhm for Signaling circuit
Toxic Heavy Metal Free:
Yes
Auxiliary Contact Composition:
1 NO
Sustainable Offer Status:
Green Premium product
Rohs Exemption Information:
Yes
[Ith] Conventional Free Air Thermal Current:
20 A (at 60°C) for power circuit || 10 A (at 50°C) for Signaling circuit
Operating Time:
10...20 ms coil energisation and NO closing || 10...20 ms coil de-energisation and NO opening
Weight:
0.39 kg
[Ui] Rated Insulation Voltage:
power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-5-1 || Signaling circuit 600 V UL 508 || power circuit 600 V CSA C22.2 No 14 || Signaling circuit 600 V CSA
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Ip Degree Of Protection:
IP20 VDE 0106
Height:
58 mm
[Uc] Control Circuit Voltage:
24 V AC 50/60 Hz
Ambient Air Temperature For Operation:
-25-50°C
Average Impedance:
3 mOhm - Ith 20 A 50 Hz for power circuit
Control Circuit Type:
AC 50/60 Hz
Mercury Free:
Yes
Depth:
57 mm
Inrush Power In Va:
30-30 VA (at 20°C)
Rated Breaking Capacity:
110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conformin
Flame Retardance:
V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
Device Application:
control
Reach Free Of Svhc:
Yes
Range:
TeSys
Standards:
EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1
Poles Description:
3P
Mechanical Robustness:
shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on X axis6 Gn for 11
Net Weight:
0.39 kg
Contactor Application:
motor control
Hold-In Power Consumption In Va:
4.5-4.5 VA (at 20°C)
Warranty:
18 months
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Connections - Terminals:
screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4
[Ie] Rated Operational Current:
6 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 6 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Tightening Torque:
0.8-1.3 N.m screw clamp terminals Philips No 2 || 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm || 0.8-1.3 N.m screw clamp terminals pozidriv No 2
Electrical Durability:
1.3 Mcycles 6 A AC-3 <= 440 V || 1.3 Mcycles 6 A AC-3e <= 440 V || 0.05 Mcycles 36 A AC-4 <= 440 V
Protective Treatment:
TC IEC 60068 || TC DIN 50016
[Icw] Rated Short-Time Withstand Current:
90 A 50°C - 1 s for power circuit || 85 A 50°C - 5 s for power circuit || 80 A 50°C - 10 s for power circuit || 60 A 50°C - 30 s for power circuit || 45 A 50°C - 1 min for power circuit || 40 A 50°C - 3 min for power circuit || 20 A 50°C - >= 15 min
$130.00

Description

LC2K0610B7 is a compact 3-pole TeSys K reversing contactor from Schneider Electric for motor applications. Rated 6A AC-3 2.2kW@400V, it includes a 24V 50/60Hz AC coil, 2NO auxiliary contacts, a mechanical interlock and pre-wired reversing circuit. LC2K0610B7 is a 3-pole TeSys K reversing contactor from Schneider Electric for simple motor applications rated up to 2.2kW@400V. Very compact, DIN-rail compatible, with connections by screw clamp terminals, it is assembled with a mechanical interlock and a pre-wired reversing circuit. It includes a 24V 50/60Hz AC coil and 2NO built-in auxiliary contacts. Available worldwide, it complies with multi-standards (IEC, UL, CSA, CCC, EAC, Marine) and is certified Green Premium (RoHs/Reach). Very compact, 90mm wide, for DIN-rail and panel mounting. Assembled with mechanical interlock and pre-wired reversing circuit. Provides a 24V AC coil compatible 50/60Hz and 2NO built-in auxiliary contact. Can be completed with auxiliary contact blocks (LA1K, LA2K) and thermal relays (LR2K).
View AllClose