Schneider Electric

Schneider Electric LC2K09004B7 Changeover contactor, TeSys K, 4P, AC-1, lt or eq to 440V 10A, 24VAC coil

(No reviews yet) Write a Review
SKU:
LC2K09004B7
MPN:
LC2K09004B7
Condition:
New
[Ie] Rated Operational Current:
20 A (at <60°C) at <= 440 V AC AC-1 for power circuit
Standards:
EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1
Mercury Free:
Yes
Tightening Torque:
0.8-1.3 N.m screw clamp terminals Philips No 2 || 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm || 0.8-1.3 N.m screw clamp terminals pozidriv No 2
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Depth:
57 mm
Circularity Profile:
ENVEOLI1503003EN
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Poles Description:
4P
Pole Contact Composition:
4 NO
Country of Origin:
France
Product Name:
TeSys K
Average Impedance:
3 mOhm - Ith 20 A 50 Hz for power circuit
Contactor Application:
resistive load
Mounting Support:
plate || rail
Ambient Air Temperature For Storage:
-50-80°C
Product Certifications:
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
Environmental Disclosure:
ENVPEP1503003EN
Operating Altitude:
6561.68 ft (2000 m) without derating
Maximum Operating Rate:
3600 cyc/h
Device Short Name:
LC2K
Irms Rated Making Capacity:
110 A AC for power circuit conforming to IEC 60947
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Ambient Air Temperature For Operation:
-25-50°C
Interlocking Type:
mechanical
[Ue] Rated Operational Voltage:
power circuit 690 V AC 50/60 Hz
Protective Treatment:
TC IEC 60068 || TC DIN 50016
Associated Fuse Rating:
25 A gG at <= 440 V for power circuit || 25 A aM for power circuit
Net Weight:
0.38 kg
Flame Retardance:
V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
Sustainable Offer Status:
Green Premium product
Device Presentation:
preassembled with reversing power busbar
Toxic Heavy Metal Free:
Yes
[Ui] Rated Insulation Voltage:
power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA C22.2 No 14
Warranty:
18 months
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Mechanical Robustness:
shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on X axis6 Gn for 11
Device Application:
control
Range:
TeSys
Ip Degree Of Protection:
IP20 VDE 0106
Eu Rohs Directive:
Compliant
Weight:
0.38 kg
Control Circuit Voltage Limits:
operational: 0.8...1.15 Uc (at <50°C) || drop-out: 0.2...0.75 Uc (at <50°C)
Reach Free Of Svhc:
Yes
Mechanical Durability:
5 Mcycles
$167.00

Description

TeSys K changeover contactor, 4 poles (4NO), for non-inductive load control applications up to 20A/690V AC-1. It provides 24V 50/60Hz AC coils, without built-in auxiliary contacts, connection by screw clamp terminals. For operating rates until 600 cycles/hour in AC-3 and environments until 50°C, it procures reliability and durability to standard applications. Compact (90mm width), DIN-rail mounting or screw fixing. With pre-wired changeover power connections, mechanical interlock (without electrical interlocking). Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
View AllClose