Schneider Electric

Schneider Electric LC2K09015F7 Reversing contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NC, 110VAC coil

(No reviews yet) Write a Review
SKU:
LC2K09015F7
MPN:
LC2K09015F7
Condition:
New
Ambient Air Temperature For Operation:
-25-50°C
Protective Treatment:
TC IEC 60068 || TC DIN 50016
[Ui] Rated Insulation Voltage:
power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-5-1 || Signaling circuit 600 V UL 508 || power circuit 600 V CSA C22.2 No 14 || Signaling circuit 600 V CSA
Average Impedance:
3 mOhm - Ith 20 A 50 Hz for power circuit
Control Circuit Voltage Limits:
operational: 0.8...1.15 Uc (at <50°C) || drop-out: 0.2...0.75 Uc (at <50°C)
Operating Altitude:
6561.68 ft (2000 m) without derating
Toxic Heavy Metal Free:
Yes
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Warranty:
18 months
Reach Free Of Svhc:
Yes
Depth:
57 mm
Environmental Disclosure:
ENVPEP1503003EN
Range:
TeSys
Poles Description:
3P
Rohs Exemption Information:
Yes
Maximum Operating Rate:
3600 cyc/h
Sustainable Offer Status:
Green Premium product
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
[Ith] Conventional Free Air Thermal Current:
20 A (at 50°C) for power circuit || 10 A (at 50°C) for Signaling circuit
Device Short Name:
LC2K
Utilisation Category:
AC-3 || AC-4 || AC-1 || AC-3e
Rated Breaking Capacity:
110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 70 A at 660...690 V conformin
Minimum Switching Voltage:
17 V for Signaling circuit
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Non Overlap Distance:
0.5 mm
Electrical Durability:
1.3 Mcycles 9 A AC-3 <= 440 V || 1.3 Mcycles 9 A AC-3e <= 440 V || 0.16 Mcycles 20 A AC-1 <= 690 V || 0.02 Mcycles 54 A AC-4 <= 440 V
Mechanical Robustness:
shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on X axis6 Gn for 11
[Ue] Rated Operational Voltage:
power circuit 690 V AC 50/60 Hz || Signaling circuit <= 690 V AC 50/60 Hz
Contactor Application:
resistive load || motor control
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Interlocking Type:
mechanical
Irms Rated Making Capacity:
110 A AC for power circuit conforming to NF C 63-110 || 110 A AC for power circuit conforming to IEC 60947 || 110 A AC for Signaling circuit conforming to IEC 60947
Product Name:
TeSys K
Associated Fuse Rating:
25 A gG at <= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947 || 10 A gG for Signaling circuit conforming to VDE 0660
Eu Rohs Directive:
Compliant
Heat Dissipation:
1.3-1.3 W
Mounting Support:
plate || rail
Operating Time:
10...20 ms coil energisation and NO closing || 10...20 ms coil de-energisation and NO opening
[Icw] Rated Short-Time Withstand Current:
90 A 50°C - 1 s for power circuit || 85 A 50°C - 5 s for power circuit || 80 A 50°C - 10 s for power circuit || 60 A 50°C - 30 s for power circuit || 45 A 50°C - 1 min for power circuit || 40 A 50°C - 3 min for power circuit || 80 A - 1 s for Signali
Mercury Free:
Yes
Signaling Circuit Frequency:
<= 400 Hz
[Ie] Rated Operational Current:
20 A (at <50°C) at <= 440 V AC AC-1 for power circuit || 16 A (at <70°C) at 690 V AC AC-1 for power circuit || 9 A at <= 440 V AC AC-3 for power circuit || 9 A at <= 440 V AC AC-3e for power circuit
Insulation Resistance:
> 10 MOhm for Signaling circuit
Auxiliary Contacts Type:
instantaneous 1 NC
Flame Retardance:
V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
Hold-In Power Consumption In Va:
4.5-4.5 VA (at 20°C)
Width:
90 mm
Control Circuit Type:
AC 50/60 Hz
Height:
58 mm
$167.00