Schneider Electric

Schneider Electric LC2K09107B7 Reversing contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NO, 24VAC coil

(No reviews yet) Write a Review
SKU:
LC2K09107B7
MPN:
LC2K09107B7
Condition:
New
[Ith] Conventional Free Air Thermal Current:
20 A (at 50°C) for power circuit || 10 A (at 50°C) for Signaling circuit
Product Or Component Type:
reversing contactor
Non Overlap Distance:
0.5 mm
Heat Dissipation:
1.3-1.3 W
Eu Rohs Directive:
Compliant
Ip Degree Of Protection:
IP20 VDE 0106
Rohs Exemption Information:
Yes
Reach Free Of Svhc:
Yes
Environmental Disclosure:
ENVPEP1503003EN
Ambient Air Temperature For Storage:
-50-80°C
Product Name:
TeSys K
Standards:
EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1
Utilisation Category:
AC-4 || AC-3 || AC-1 || AC-3e
Circularity Profile:
ENVEOLI1503003EN
Toxic Heavy Metal Free:
Yes
Associated Fuse Rating:
25 A gG at <= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947 || 10 A gG for Signaling circuit conforming to VDE 0660
[Ui] Rated Insulation Voltage:
power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-5-1 || Signaling circuit 600 V UL 508 || power circuit 600 V CSA C22.2 No 14 || Signaling circuit 600 V CSA
Ambient Air Temperature For Operation:
-25-50°C
Insulation Resistance:
> 10 MOhm for Signaling circuit
[Icw] Rated Short-Time Withstand Current:
90 A 50°C - 1 s for power circuit || 85 A 50°C - 5 s for power circuit || 80 A 50°C - 10 s for power circuit || 60 A 50°C - 30 s for power circuit || 45 A 50°C - 1 min for power circuit || 40 A 50°C - 3 min for power circuit || 80 A - 1 s for Signali
[Ue] Rated Operational Voltage:
power circuit 690 V AC 50/60 Hz || Signaling circuit <= 690 V AC 50/60 Hz
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Signaling Circuit Frequency:
<= 400 Hz
[Ie] Rated Operational Current:
20 A (at <50°C) at <= 440 V AC AC-1 for power circuit || 16 A (at <70°C) at 690 V AC AC-1 for power circuit || 9 A at <= 440 V AC AC-3 for power circuit || 9 A at <= 440 V AC AC-3e for power circuit
Connections - Terminals:
Faston terminals 2 2.8 mm) || Faston terminals 1 6.35 mm)
Overvoltage Category:
III
Operating Altitude:
6561.68 ft (2000 m) without derating
Width:
90 mm
Mounting Support:
plate || rail
Sustainable Offer Status:
Green Premium product
Minimum Switching Voltage:
17 V for Signaling circuit
Device Short Name:
LC2K
Country of Origin:
France
Device Presentation:
preassembled with reversing power busbar
Control Circuit Voltage Limits:
operational: 0.8...1.15 Uc (at <50°C) || drop-out: 0.2...0.75 Uc (at <50°C)
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Maximum Operating Rate:
3600 cyc/h
Mercury Free:
Yes
Product Certifications:
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
Average Impedance:
3 mOhm - Ith 20 A 50 Hz for power circuit
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Poles Description:
3P
Weight:
0.39 kg
Warranty:
18 months
Hold-In Power Consumption In Va:
4.5-4.5 VA (at 20°C)
Flame Retardance:
V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
$167.00