Schneider Electric

Schneider Electric LC2K12004F7 Changeover contactor, TeSys K, 4P, AC-1, lt or eq to 440V 10A, 110VAC coil

(No reviews yet) Write a Review
SKU:
LC2K12004F7
MPN:
LC2K12004F7
Condition:
New
Rated Breaking Capacity:
110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conforming to IEC 60947
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Connections - Terminals:
screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4
[Uc] Control Circuit Voltage:
110 V AC 50/60 Hz
Operating Time:
10...20 ms coil energisation and NO closing || 10...20 ms coil de-energisation and NO opening
Hold-In Power Consumption In Va:
4.5-4.5 VA (at 20°C)
Protective Treatment:
TC IEC 60068 || TC DIN 50016
Width:
90 mm
Heat Dissipation:
1.3-1.3 W
Rohs Exemption Information:
Yes
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Utilisation Category:
AC-1
Product Or Component Type:
changeover contactor
Pole Contact Composition:
4 NO
Maximum Operating Rate:
3600 cyc/h
[Ui] Rated Insulation Voltage:
power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA C22.2 No 14
Toxic Heavy Metal Free:
Yes
Environmental Disclosure:
ENVPEP1503003EN
[Icw] Rated Short-Time Withstand Current:
115 A 50°C - 1 s for power circuit || 105 A 50°C - 5 s for power circuit || 100 A 50°C - 10 s for power circuit || 75 A 50°C - 30 s for power circuit || 55 A 50°C - 1 min for power circuit || 50 A 50°C - 3 min for power circuit || 25 A 50°C - >= 15 m
Tightening Torque:
0.8-1.3 N.m screw clamp terminals Philips No 2 || 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm || 0.8-1.3 N.m screw clamp terminals pozidriv No 2
Poles Description:
4P
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Mechanical Durability:
5 Mcycles
Range:
TeSys
[Ith] Conventional Free Air Thermal Current:
20 A (at 60°C) for power circuit
Inrush Power In Va:
30-30 VA (at 20°C)
[Ie] Rated Operational Current:
20 A (at <60°C) at <= 440 V AC AC-1 for power circuit
Net Weight:
0.38 kg
Depth:
57 mm
Associated Fuse Rating:
25 A gG at <= 440 V for power circuit || 25 A aM for power circuit
Mounting Support:
plate || rail
Overvoltage Category:
III
Ambient Air Temperature For Storage:
-50-80°C
Sustainable Offer Status:
Green Premium product
Product Name:
TeSys K
Eu Rohs Directive:
Compliant
Mechanical Robustness:
shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on X axis6 Gn for 11
Standards:
EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1
Device Presentation:
preassembled with reversing power busbar
[Ue] Rated Operational Voltage:
power circuit 690 V AC 50/60 Hz
Control Circuit Type:
AC 50/60 Hz
Warranty:
18 months
Control Circuit Voltage Limits:
operational: 0.8...1.15 Uc (at <50°C) || drop-out: 0.2...0.75 Uc (at <50°C)
Reach Free Of Svhc:
Yes
Flame Retardance:
V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
Electrical Durability:
0.16 Mcycles 20 A AC-1 <= 690 V
Circularity Profile:
ENVEOLI1503003EN
$191.00