LC2K1201U7 is a compact 3-pole TeSys K reversing contactor from Schneider Electric for motor applications. Rated 12A AC-3 5.5kW@400V, it includes a 240V 50/60Hz AC coil, 2NC auxiliary contacts, a mechanical interlock and pre-wired reversing circuit. LC2K1201U7 is a 3-pole TeSys K reversing contactor from Schneider Electric for simple motor applications rated up to 5.5kW@400V. Very compact, DIN-rail compatible, with connections by screw clamp terminals, it is assembled with a mechanical interlock and a pre-wired reversing circuit. It includes a 240V 50/60Hz AC coil and 2NC built-in auxiliary contacts. Available worldwide, it complies with multi-standards (IEC, UL, CSA, CCC, EAC, Marine) and is certified Green Premium (RoHs/Reach). Very compact, 90mm wide, for DIN-rail and panel mounting. Assembled with mechanical interlock and pre-wired reversing circuit. Provides a 240V AC coil compatible 50/60Hz and 2NC built-in auxiliary contact. Can be completed with auxiliary contact blocks (LA1K, LA2K) and thermal relays (LR2K).
- [Ui] Rated Insulation Voltage:
- power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-5-1 || Signaling circuit 600 V UL 508 || power circuit 600 V CSA C22.2 No 14 || Signaling circuit 600 V CSA
- Width:
- 90 mm
- Net Weight:
- 0.39 kg
- Pole Contact Composition:
- 3 NO
- [Ie] Rated Operational Current:
- 12 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 12 A (at <60°C) at <= 440 V AC AC-3e for power circuit || 20 A (at <60°C) at <= 690 V AC AC-1 for power circuit
- Product Certifications:
- CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
- Ambient Air Temperature For Storage:
- -50-80°C
- Rohs Exemption Information:
- Yes
- Connections - Terminals:
- screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4
- Operating Time:
- 10...20 ms coil energisation and NO closing || 10...20 ms coil de-energisation and NO opening
- Non Overlap Distance:
- 0.5 mm
- Toxic Heavy Metal Free:
- Yes
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- Weight:
- 0.39 kg
- [Uc] Control Circuit Voltage:
- 230...240 V AC 50/60 Hz
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Overvoltage Category:
- III
- Operating Altitude:
- 6561.68 ft (2000 m) without derating
- Signaling Circuit Frequency:
- <= 400 Hz
- Range:
- TeSys
- Flame Retardance:
- V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
- Auxiliary Contact Composition:
- 1 NC
- Mounting Support:
- rail || plate
- Auxiliary Contacts Type:
- instantaneous 1 NC
- Poles Description:
- 3P
- Product Name:
- TeSys K
- Reach Free Of Svhc:
- Yes
- Rated Breaking Capacity:
- 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conforming to IEC 60947
- Heat Dissipation:
- 1.3-1.3 W
- Associated Fuse Rating:
- 25 A gG at <= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947 || 10 A gG for Signaling circuit conforming to VDE 0660
- Maximum Operating Rate:
- 3600 cyc/h
- Depth:
- 57 mm
- [Ith] Conventional Free Air Thermal Current:
- 20 A (at 60°C) for power circuit || 10 A (at 50°C) for Signaling circuit
- Mechanical Durability:
- 5 Mcycles
- Inrush Power In Va:
- 30-30 VA (at 20°C)
- Irms Rated Making Capacity:
- 144 A AC for power circuit conforming to IEC 60947 || 110 A AC for Signaling circuit conforming to IEC 60947
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Protective Treatment:
- TC IEC 60068 || TC DIN 50016
- [Icw] Rated Short-Time Withstand Current:
- 115 A 50°C - 1 s for power circuit || 105 A 50°C - 5 s for power circuit || 100 A 50°C - 10 s for power circuit || 75 A 50°C - 30 s for power circuit || 55 A 50°C - 1 min for power circuit || 50 A 50°C - 3 min for power circuit || 25 A 50°C - >= 15 m
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Eu Rohs Directive:
- Compliant
- Country of Origin:
- France
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Device Presentation:
- preassembled with reversing power busbar
- Device Application:
- control
- Circularity Profile:
- ENVEOLI1503003EN
- Mercury Free:
- Yes
- Ambient Air Temperature For Operation:
- -25-50°C