Schneider Electric

Schneider Electric LC2K1210K7 Reversing contactor, TeSys K, 3P, AC-3, lt or eq to 440V 12 A, 1 NO, 100VAC coil

(No reviews yet) Write a Review
SKU:
LC2K1210K7
MPN:
LC2K1210K7
Condition:
New
Contactor Application:
motor control || resistive load
Hold-In Power Consumption In Va:
4.5-4.5 VA (at 20°C)
Country of Origin:
France
Device Short Name:
LC2K
Non Overlap Distance:
0.5 mm
Overvoltage Category:
III
Ip Degree Of Protection:
IP20 VDE 0106
Associated Fuse Rating:
25 A gG at <= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947 || 10 A gG for Signaling circuit conforming to VDE 0660
Product Name:
TeSys K
Product Or Component Type:
reversing contactor
Ambient Air Temperature For Storage:
-50-80°C
Minimum Switching Current:
5 mA for Signaling circuit
Standards:
EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1
Mercury Free:
Yes
Environmental Disclosure:
ENVPEP1503003EN
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Auxiliary Contact Composition:
1 NO
Maximum Operating Rate:
3600 cyc/h
[Ith] Conventional Free Air Thermal Current:
20 A (at 50°C) for power circuit || 10 A (at 50°C) for Signaling circuit
Height:
58 mm
Minimum Switching Voltage:
17 V for Signaling circuit
Range:
TeSys
[Icw] Rated Short-Time Withstand Current:
115 A 50°C - 1 s for power circuit || 105 A 50°C - 5 s for power circuit || 100 A 50°C - 10 s for power circuit || 75 A 50°C - 30 s for power circuit || 55 A 50°C - 1 min for power circuit || 50 A 50°C - 3 min for power circuit || 80 A - 1 s for Sign
[Ie] Rated Operational Current:
20 A (at <50°C) at <= 440 V AC AC-1 for power circuit || 16 A (at <70°C) at 690 V AC AC-1 for power circuit || 12 A at <= 440 V AC AC-3 for power circuit
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
[Uc] Control Circuit Voltage:
100 V AC 50/60 Hz
Heat Dissipation:
1.3-1.3 W
Operating Time:
10...20 ms coil energisation and NO closing || 10...20 ms coil de-energisation and NO opening
Mounting Support:
rail || plate
Electrical Durability:
1.3 Mcycles 12 A AC-3 <= 440 V || 1.3 Mcycles 12 A AC-3e <= 440 V || 0.3 Mcycles 20 A AC-1 <= 690 V || 0.02 Mcycles 72 A AC-4 <= 440 V
Eu Rohs Directive:
Compliant
Circularity Profile:
ENVEOLI1503003EN
Control Circuit Type:
AC 50/60 Hz
Insulation Resistance:
> 10 MOhm for Signaling circuit
Inrush Power In Va:
30-30 VA (at 20°C)
California Proposition 65:
WARNING: Cancer - www.P65Warnings.ca.gov
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Sustainable Offer Status:
Green Premium product
Width:
90 mm
Control Circuit Voltage Limits:
operational: 0.85...1.1 Uc (at <50°C) || drop-out: 0.2...0.75 Uc (at <50°C)
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Tightening Torque:
0.8-1.3 N.m screw clamp terminals Philips No 2 || 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm || 0.8-1.3 N.m screw clamp terminals pozidriv No 2
Mechanical Durability:
5 Mcycles
Product Certifications:
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
[Ui] Rated Insulation Voltage:
power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-5-1 || Signaling circuit 600 V UL 508 || power circuit 600 V CSA C22.2 No 14 || Signaling circuit 600 V CSA
Weight:
0.39 kg
Reach Free Of Svhc:
Yes
Net Weight:
0.39 kg
[Ue] Rated Operational Voltage:
power circuit 690 V AC 50/60 Hz || Signaling circuit <= 690 V AC 50/60 Hz
Mechanical Robustness:
shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on X axis6 Gn for 11