Schneider Electric LC3D115P7A64 Star delta starter, TeSys Deca, 3x3P(3NO), 115A, 230V AC coil, screw clamp terminal
Schneider Electric
$1,915.00
Star delta starter, TeSys Deca, 3x3P(3NO), 115A, 230V AC coil, screw clamp terminal
- Ambient Air Temperature For Operation:
- -40-60°C || 60-70°C with derating
- Auxiliary Contacts Type:
- mechanically linked IEC 60947-5-1 3 x 1 NO + 1 NC || mirror contact IEC 60947-4-1 3 x 1 NC
- Height:
- 555 mm
- Pole Contact Composition:
- 3 x 3 NO
- Poles Description:
- 3 x 3P
- Control Circuit Type:
- AC 50/60 Hz
- Reach Free Of Svhc:
- Yes
- Product Or Component Type:
- star delta starter
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- Heat Dissipation:
- 3-8 W 50/60 Hz
- Protective Treatment:
- TH IEC 60068-2-30
- Circularity Profile:
- ENVEOLI100405EN
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Environmental Disclosure:
- ENVPEP060301EN
- Product Certifications:
- CSA || BV || GL || CCC || GOST || UL || DNV || LROS (Lloyds register of shipping) || RINA
- Ambient Air Temperature For Storage:
- -60-80°C
- Pvc Free:
- Yes
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Depth:
- 205 mm
- Device Short Name:
- LC3D
- Rohs Exemption Information:
- Yes
- Sustainable Offer Status:
- Green Premium product
- Auxiliary Contact Composition:
- 1 NC KM2 line contactor || 1 NO KM3 delta contactor
- Warranty:
- 18 months
- [Ui] Rated Insulation Voltage:
- power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 1000 V IEC 60947-4-1 || Signaling circuit 1000 V IEC 60947-1
- Contactor Application:
- motor control
- Coil Technology:
- without built-in suppressor module
- [Ie] Rated Operational Current:
- 115 A (at <60°C) at <= 440 V AC AC-3 for power circuit
- Weight:
- 12.1 kg
- Starting Time:
- 30 s
- Fire Resistance:
- 850°C IEC 60695-2-1
- Eu Rohs Directive:
- Compliant
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Pollution Degree:
- 3
- Flame Retardance:
- V1 conforming to UL 94
- Maximum Operating Rate:
- 30 cyc/h 60°C
- Mechanical Robustness:
- vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor closed15 Gn for 11 ms || shocks contactor open6 Gn for 11 ms
- Device Presentation:
- pre-wired
- Connections - Terminals:
- power circuit: connector 1 10-120 mm² - cable stiffness: flexible without cable end || power circuit: connector 2 10-50 mm² - cable stiffness: flexible without cable end || power circuit: connector 1 10-120 mm² - cable stiffness: flexible with cab
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz
- Country of Origin:
- France
- Electrical Durability:
- 0.95 Mcycles 115 A AC-3 <= 440 V
- Mercury Free:
- Yes
- [Uc] Control Circuit Voltage:
- 230 V AC 50/60 Hz
- Switching Voltage:
- 17 V Signaling circuit
- Product Name:
- TeSys Deca
- Overvoltage Category:
- III
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Width:
- 450 mm