Schneider Electric

Schneider Electric LC3D12AP7 TeSys Deca , star delta starter , 3 x 3P (3 NO) , 12 A , 230 V AC coil

(No reviews yet) Write a Review
SKU:
LC3D12AP7
MPN:
LC3D12AP7
Condition:
New
Height:
124 mm
Mechanical Durability:
15 Mcycles
Mounting Support:
plate
Pollution Degree:
3
Connections - Terminals:
power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || power circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || power circuit: screw clamp terminals 1 1-4 mm² - cable
Maximum Operating Rate:
30 cyc/h 60°C
[Ie] Rated Operational Current:
12 A (at <60°C) at <= 440 V AC AC-3 for power circuit
Inrush Power In Va:
70-70 VA 60 Hz cos phi 0.75 (at 20°C) || 70-70 VA 50 Hz cos phi 0.75 (at 20°C)
Coil Technology:
without built-in suppressor module
Mercury Free:
Yes
Control Circuit Voltage Limits:
drop-out: 0.3...0.6 Uc at 50/60 Hz (at <60°C) || operational: 0.8...1.1 Uc at 50 Hz (at <60°C) || operational: 0.85...1.1 Uc at 60 Hz (at <60°C)
Utilisation Category:
AC-3
Device Presentation:
pre-wired
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Starting Time:
30 s
Operating Altitude:
9842.52 ft (3000 m) without derating
Environmental Disclosure:
ENVPEP1501004
Pvc Free:
Yes
Weight:
1.53 kg
Motor Power Kw:
11 kW 380/400 V AC 50/60 Hz || 11 kW 415 V AC 50/60 Hz || 11 kW 440 V AC 50/60 Hz || 5.5 kW 220/230 V AC 50/60 Hz
Provided Equipment:
protective cover
Auxiliary Contacts Type:
mechanically linked IEC 60947-5-1 3 x 1 NO + 1 NC || mirror contact IEC 60947-4-1 3 x 1 NC
Rohs Exemption Information:
Yes
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz
Switching Voltage:
17 V Signaling circuit
Depth:
143 mm
Product Or Component Type:
star delta starter
Poles Description:
3 x 3P
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Insulation Resistance:
> 10 MOhm for Signaling circuit
Ip Degree Of Protection:
IP20 front face IEC 60529
Circularity Profile:
ENVEOLI1501004
Fire Resistance:
850°C IEC 60695-2-1
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Range:
TeSys || TeSys Deca
Climatic Withstand:
IACS E10 || IEC 60947-1 Annex Q category D
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
Minimum Switching Current:
5 mA for Signaling circuit
Country of Origin:
France
Overvoltage Category:
III
Device Short Name:
LC3D
[Uc] Control Circuit Voltage:
230 V AC 50/60 Hz
Ambient Air Temperature For Storage:
-60-80°C
Hold-In Power Consumption In Va:
7.5-7.5 VA 60 Hz cos phi 0.3 (at 20°C) || 7-7 VA 50 Hz cos phi 0.3 (at 20°C)
Pole Contact Composition:
3 x 3 NO
Protective Treatment:
TH IEC 60068-2-30
Sustainable Offer Status:
Green Premium product
$1,976.00

Description

TeSys D pre-assembled star-delta starter, for motor control applications up to 11kW@400V in delta connection. Plate mounted starter, open version, composed of 3 contactors LC1D with 230V 50/60Hz AC coils, 1NC built-in auxiliary contact on star, a time-delay contact block 1-30 sec. For operating rates until 30 starts/hour, maximum starting time 30 sec. Compact assembly (144mm width), screw fixing. Equipped with pre-wired star delta power connections, and mechanical interlock, the use of a thermal overload relay (to be ordered separately) is strongly recommended. Green Premium compliant (RoHS/REACh).
View AllClose