Pole Contact Composition:
3 x 3 NO
Minimum Switching Current:
5 mA for Signaling circuit
Inrush Power In Va:
70-70 VA 60 Hz cos phi 0.75 (at 20°C) || 70-70 VA 50 Hz cos phi 0.75 (at 20°C)
[Uc] Control Circuit Voltage:
230 V AC 50/60 Hz
Pollution Degree:
3
Standards:
EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || CSA C22.2 No 14 || UL 508 || IEC 60335-1
Warranty:
18 months
Connections - Terminals:
control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 1 1-4 mm² -
Device Presentation:
pre-wired
Control Circuit Voltage Limits:
drop-out: 0.3...0.6 Uc at 50/60 Hz (at <60°C) || operational: 0.8...1.1 Uc at 50 Hz (at <60°C) || operational: 0.85...1.1 Uc at 60 Hz (at <60°C)
Mechanical Robustness:
vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor open10 Gn for 11 ms || shocks contactor closed15 Gn for 11 ms
[Ie] Rated Operational Current:
18 A (at <60°C) at <= 440 V AC AC-3 for power circuit
Circularity Profile:
ENVEOLI1501004
Country of Origin:
France
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz
Flame Retardance:
V1 conforming to UL 94
Contactor Application:
motor control
Signaling Circuit Frequency:
25...400 Hz
Utilisation Category:
AC-3
Auxiliary Contacts Type:
mechanically linked IEC 60947-5-1 3 x 1 NO + 1 NC || mirror contact IEC 60947-4-1 3 x 1 NC
Product Name:
TeSys Deca
Coil Technology:
without built-in suppressor module
Operating Altitude:
9842.52 ft (3000 m) without derating
Mounting Support:
rail
Ambient Air Temperature For Operation:
-40-70°C at Uc
Hold-In Power Consumption In Va:
7.5-7.5 VA 60 Hz cos phi 0.3 (at 20°C) || 7-7 VA 50 Hz cos phi 0.3 (at 20°C)
Depth:
143 mm
Poles Description:
3 x 3P
Range:
TeSys || TeSys Deca
Maximum Operating Rate:
30 cyc/h 60°C
Fire Resistance:
850°C IEC 60695-2-1
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 1000 V IEC 60947-4-1 || Signaling circuit 1000 V IEC 60947-1
Switching Voltage:
17 V Signaling circuit
Net Weight:
1.73 kg
Rohs Exemption Information:
Yes
Electrical Durability:
1.65 Mcycles 18 A AC-3 <= 440 V
Toxic Heavy Metal Free:
Yes
Heat Dissipation:
2-3 W 50/60 Hz
Control Circuit Type:
AC 50/60 Hz
Ip Degree Of Protection:
IP20 front face IEC 60529
Climatic Withstand:
IACS E10 || IEC 60947-1 Annex Q category D
Sustainable Offer Status:
Green Premium product
Eu Rohs Directive:
Compliant
Starting Time:
30 s
Height:
124 mm
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
$2,588.00

Description

TeSys D pre-assembled star-delta starter, for motor control applications up to 11kW@400V in delta connection. Plate mounted starter, open version, composed of 3 contactors LC1D with 230V 50/60Hz AC coils, 1NC built-in auxiliary contact on star, a time-delay contact block 1-30 sec. For operating rates until 30 starts/hour, maximum starting time 30 sec. Compact assembly (144mm width), screw fixing. Equipped with pre-wired star delta power connections, and mechanical interlock, the use of a thermal overload relay (to be ordered separately) is strongly recommended. Green Premium compliant (RoHS/REACh).