Schneider Electric

Schneider Electric LC3D18AU7 TeSys Deca , star delta starter , 3 x 3P (3 NO) , 18 A , 240 V AC coil

(No reviews yet) Write a Review
SKU:
LC3D18AU7
MPN:
LC3D18AU7
Condition:
New
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Maximum Operating Rate:
30 cyc/h 60°C
Mounting Support:
plate
Starting Time:
30 s
[Ie] Rated Operational Current:
18 A (at <60°C) at <= 440 V AC AC-3 for power circuit
Product Or Component Type:
star delta starter
Device Presentation:
pre-wired
Ip Degree Of Protection:
IP20 front face IEC 60529
Poles Description:
3 x 3P
Circularity Profile:
ENVEOLI1501004
Ambient Air Temperature For Operation:
-40-70°C at Uc
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Warranty:
18 months
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Standards:
EN 60947-4-1 || CSA C22.2 No 14 || IEC 60947-4-1 || UL 508 || EN 60947-5-1 || IEC 60947-5-1 || IEC 60335-1
Fire Resistance:
850°C IEC 60695-2-1
Device Short Name:
LC3D
Toxic Heavy Metal Free:
Yes
Height:
124 mm
Overvoltage Category:
III
Interlocking Type:
mechanical
Mercury Free:
Yes
Switching Voltage:
17 V Signaling circuit
Pvc Free:
Yes
Utilisation Category:
AC-3
Inrush Power In Va:
70-70 VA 60 Hz cos phi 0.75 (at 20°C) || 70-70 VA 50 Hz cos phi 0.75 (at 20°C)
Hold-In Power Consumption In Va:
7.5-7.5 VA 60 Hz cos phi 0.3 (at 20°C) || 7-7 VA 50 Hz cos phi 0.3 (at 20°C)
Motor Power Kw:
11 kW 220/230 V AC 50/60 Hz || 22 kW 415 V AC 50/60 Hz || 22 kW 440 V AC 50/60 Hz || 18.5 kW 380/400 V AC 50/60 Hz
Pollution Degree:
3
Coil Technology:
without built-in suppressor module
Protective Treatment:
TH IEC 60068-2-30
Insulation Resistance:
> 10 MOhm for Signaling circuit
Mechanical Robustness:
vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor open10 Gn for 11 ms || shocks contactor closed15 Gn for 11 ms
Net Weight:
1.73 kg
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Country of Origin:
France
Control Circuit Voltage Limits:
drop-out: 0.3...0.6 Uc at 50/60 Hz (at <60°C) || operational: 0.8...1.1 Uc at 50 Hz (at <60°C) || operational: 0.85...1.1 Uc at 60 Hz (at <60°C)
Provided Equipment:
protective cover
Flame Retardance:
V1 conforming to UL 94
Tightening Torque:
power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power
Range:
TeSys || TeSys Deca
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
Depth:
143 mm
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz
Control Circuit Type:
AC 50/60 Hz
Connections - Terminals:
control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 1 1-4 mm² -
Rohs Exemption Information:
Yes
$673.00

Description

TeSys D pre-assembled star-delta starter, for motor control applications up to 18.5kW@400V in delta connection. Plate mounted starter, open version, composed of 3 contactors LC1D with 240V 50/60Hz AC coils, 1NC built-in auxiliary contact on star, a time-delay contact block 1-30 sec. For operating rates until 30 starts/hour, maximum starting time 30 sec. Compact assembly (144mm width), screw fixing. Equipped with pre-wired star delta power connections, and mechanical interlock, the use of a thermal overload relay (to be ordered separately) is strongly recommended. Green Premium compliant (RoHS/REACh).
View AllClose