- Product Or Component Type:
- star delta starter
- Climatic Withstand:
- IACS E10 || IEC 60947-1 Annex Q category D
- Warranty:
- 18 months
- Sustainable Offer Status:
- Green Premium product
- Circularity Profile:
- ENVEOLI110229EN
- Mercury Free:
- Yes
- Overvoltage Category:
- III
- Standards:
- EN 60947-5-1 || EN 60947-4-1 || UL 508 || CSA C22.2 No 14 || IEC 60947-4-1 || IEC 60947-5-1 || IEC 60335-1
- Signaling Circuit Frequency:
- 25...400 Hz
- Inrush Power In Va:
- 70-70 VA 60 Hz cos phi 0.75 (at 20°C) || 70-70 VA 50 Hz cos phi 0.75 (at 20°C)
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Control Circuit Voltage Limits:
- drop-out: 0.3...0.6 Uc at 50/60 Hz (at <60°C) || operational: 0.8...1.1 Uc at 50 Hz (at <60°C) || operational: 0.85...1.1 Uc at 60 Hz (at <60°C)
- Electrical Durability:
- 1.65 Mcycles 32 A AC-3 <= 440 V
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Utilisation Category:
- AC-3
- Ambient Air Temperature For Operation:
- -40-70°C at Uc
- Net Weight:
- 2.03 kg
- Connections - Terminals:
- control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 1 1-4 mm² -
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- [Ie] Rated Operational Current:
- 32 A (at <60°C) at <= 440 V AC AC-3 for power circuit
- Hold-In Power Consumption In Va:
- 7.5-7.5 VA 60 Hz cos phi 0.3 (at 20°C) || 7-7 VA 50 Hz cos phi 0.3 (at 20°C)
- Starting Time:
- 30 s
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Control Circuit Type:
- AC 50/60 Hz
- Fire Resistance:
- 850°C IEC 60695-2-1
- Interlocking Type:
- mechanical
- Tightening Torque:
- control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 2.5 N.m screw clamp terminals flat Ø 6 mm || power circuit 2.5 N.m screw clamp terminals Philips No 2 || power
- Product Name:
- TeSys Deca
- [Uc] Control Circuit Voltage:
- 110 V AC 50/60 Hz
- Device Short Name:
- LC3D
- Pole Contact Composition:
- 3 x 3 NO
- Maximum Operating Rate:
- 30 cyc/h 60°C
- Mechanical Durability:
- 15 Mcycles
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz
- Toxic Heavy Metal Free:
- Yes
- Provided Equipment:
- protective cover
- Range:
- TeSys || TeSys Deca
- Depth:
- 149 mm
- Operating Altitude:
- 9842.52 ft (3000 m) without derating
- Eu Rohs Directive:
- Compliant
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Mounting Support:
- plate
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Poles Description:
- 3 x 3P
- Coil Technology:
- without built-in suppressor module
- Motor Power Kw:
- 15 kW 220/230 V AC 50/60 Hz || 25 kW 380/400 V AC 50/60 Hz || 30 kW 415 V AC 50/60 Hz || 30 kW 440 V AC 50/60 Hz