Schneider Electric

Schneider Electric LC3D80P7A64 TeSys Deca - star delta starter - 3 x 3P (3 NO) - 80 A - 230 V AC coil

(No reviews yet) Write a Review
SKU:
LC3D80P7A64
MPN:
LC3D80P7A64
Condition:
New
Pole Contact Composition:
3 x 3 NO
Rohs Exemption Information:
Yes
Product Name:
TeSys Deca
Auxiliary Contacts Type:
mechanically linked IEC 60947-5-1 3 x 1 NO + 1 NC || mirror contact IEC 60947-4-1 3 x 1 NC
Mercury Free:
Yes
Height:
143 mm
Poles Description:
3 x 3P
Switching Voltage:
17 V Signaling circuit
Interlocking Type:
mechanical
Hold-In Power Consumption In Va:
13-13 VA 60 Hz cos phi 0.3 (at 20°C) || 15-15 VA 50 Hz cos phi 0.3 (at 20°C)
Control Circuit Voltage Limits:
drop-out: 0.3...0.6 Uc at 50/60 Hz (at <55°C) || operational: 0.8...1.1 Uc at 50 Hz (at <55°C) || operational: 0.85...1.1 Uc at 60 Hz (at <55°C)
Reach Free Of Svhc:
Yes
Country of Origin:
France
Product Or Component Type:
star delta starter
Operating Altitude:
9842.52 ft (3000 m)
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947
Ip Degree Of Protection:
IP20 front face IEC 60529
Width:
311 mm
Ambient Air Temperature For Operation:
-40-60°C || 60-70°C with derating
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Connections - Terminals:
control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-2.5 mm²
Auxiliary Contact Composition:
1 NC KM2 line contactor || 1 NO KM3 delta contactor
Contactor Application:
motor control
Environmental Disclosure:
ENVPEP110205EN
Inrush Power In Va:
140-140 VA 60 Hz cos phi 0.75 (at 20°C) || 160-160 VA 50 Hz cos phi 0.75 (at 20°C)
Sustainable Offer Status:
Green Premium product
Mechanical Robustness:
vibrations contactor open2 Gn, 5...300 Hz || shocks contactor open8 Gn for 11 ms || vibrations contactor closed3 Gn, 5...300 Hz || shocks contactor closed10 Gn for 11 ms
Range:
TeSys
Signaling Circuit Frequency:
25...400 Hz
Device Short Name:
LC3D
Starting Time:
30 s
[Ie] Rated Operational Current:
80 A (at <60°C) at <= 440 V AC AC-3 for power circuit
Net Weight:
5.4 kg
Pvc Free:
Yes
Warranty:
18 months
Maximum Operating Rate:
30 cyc/h 60°C
Circularity Profile:
N/A
Overvoltage Category:
III
Device Presentation:
pre-wired
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 1000 V IEC 60947-4-1 || Signaling circuit 1000 V IEC 60947-1
Protective Treatment:
TH IEC 60068-2-30
[Uc] Control Circuit Voltage:
230 V AC 50/60 Hz
Ambient Air Temperature For Storage:
-60-80°C
Heat Dissipation:
4-5 W 50/60 Hz
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Fire Resistance:
850°C IEC 60695-2-1
Mechanical Durability:
4 Mcycles
Depth:
183 mm
Standards:
EN 60947-4-1 || IEC 60947-4-1 || EN 60947-5-1 || UL 508 || IEC 60947-5-1 || CSA C22.2 No 14