Schneider Electric

Schneider Electric LC7K0601M7 Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 6A, 1 NC aux., 220 to 230VAC coil

(No reviews yet) Write a Review
SKU:
LC7K0601M7
MPN:
LC7K0601M7
Condition:
New
Range:
TeSys
Ip Degree Of Protection:
IP2X VDE 0106
Overvoltage Category:
III
Poles Description:
3P
Net Weight:
0.225 kg
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
[Uc] Control Circuit Voltage:
220...230 V AC 50/60 Hz
Device Application:
control
Sustainable Offer Status:
Green Premium product
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Minimum Switching Voltage:
17 V for Signaling circuit
Signaling Circuit Frequency:
<= 400 Hz
Control Circuit Voltage Limits:
operational: 0.85...1.1 Uc (at <50°C) || drop-out: >= 0.10 Uc (at <50°C)
Pole Contact Composition:
3 NO
Contactor Application:
motor control
Rohs Exemption Information:
Yes
Protective Treatment:
TC IEC 60068 || TC DIN 50016
Circularity Profile:
ENVEOLI1503003EN
Warranty:
18 months
Weight:
0.225 kg
Eu Rohs Directive:
Compliant with Exemptions
Control Circuit Type:
AC 50/60 Hz silent
Hold-In Power Consumption In Va:
3-3 VA (at 20°C)
Mechanical Durability:
10 Mcycles
Maximum Operating Rate:
3600 cyc/h
Auxiliary Contact Composition:
1 NC
Tightening Torque:
0.8-1.3 N.m screw clamp terminals Philips No 2 || 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm || 0.8-1.3 N.m screw clamp terminals pozidriv No 2
Electrical Durability:
1.3 Mcycles 6 A AC-3 <= 440 V || 1.3 Mcycles 6 A AC-3e <= 440 V || 0.05 Mcycles 36 A AC-4 <= 440 V
Auxiliary Contacts Type:
instantaneous 1 NC
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC <= 400 Hz || Signaling circuit <= 690 V AC <= 400 Hz
Utilisation Category:
AC-3 || AC-3e || AC-4
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Insulation Resistance:
> 10 MOhm for Signaling circuit
[Ui] Rated Insulation Voltage:
power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-5-1 || Signaling circuit 600 V UL 508 || power circuit 600 V CSA C22.2 No 14 || Signaling circuit 600 V CSA
Country of Origin:
France
Ambient Air Temperature For Storage:
-50-80°C
Average Impedance:
3 mOhm - Ith 20 A 50 Hz for power circuit
Mounting Support:
rail || plate
Connections - Terminals:
screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4
Mercury Free:
Yes
Device Short Name:
LC7K
Associated Fuse Rating:
25 A gG at <= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947 || 10 A gG for Signaling circuit conforming to VDE 0660
Inrush Power In Va:
3-3 VA (at 20°C)
[Ith] Conventional Free Air Thermal Current:
20 A (at 60°C) for power circuit || 10 A (at 50°C) for Signaling circuit
[Ie] Rated Operational Current:
6 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 6 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Standards:
EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1
Motor Power Kw:
1.5 kW 220...230 V AC 50/60 Hz AC-3 || 2.2 kW 380...415 V AC 50/60 Hz AC-3 || 3 kW 440/690 V AC 50/60 Hz AC-3 || 1.5 kW 220...230 V AC 50/60 Hz AC-3e || 2.2 kW 380...415 V AC 50/60 Hz AC-3e || 3 kW 440/690 V AC 50/60 Hz AC-3e || 1.5 kW 220...230 V AC
$128.00