Schneider Electric

Schneider Electric LC7K09004B7 Contactor, TeSys K, 4P, 4 NO, AC-1, lt or eq to 440V 10A, 24VAC coil

(No reviews yet) Write a Review
SKU:
LC7K09004B7
MPN:
LC7K09004B7
Condition:
New
Operating Time:
30...40 ms coil energisation and NO closing || 30 ms coil de-energisation and NO opening
Flame Retardance:
V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
Ambient Air Temperature For Storage:
-50-80°C
Depth:
57 mm
[Icw] Rated Short-Time Withstand Current:
90 A 50°C - 1 s for power circuit || 85 A 50°C - 5 s for power circuit || 80 A 50°C - 10 s for power circuit || 60 A 50°C - 30 s for power circuit || 45 A 50°C - 1 min for power circuit || 40 A 50°C - 3 min for power circuit || 20 A 50°C - >= 15 min
Standards:
EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1
Overvoltage Category:
III
Associated Fuse Rating:
25 A gG at <= 440 V for power circuit || 25 A aM for power circuit
Utilisation Category:
AC-1
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Environmental Disclosure:
ENVPEP1503003EN
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Pole Contact Composition:
4 NO
Hold-In Power Consumption In Va:
3-3 VA (at 20°C)
Device Short Name:
LC7K
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Device Application:
control
Tightening Torque:
0.8-1.3 N.m screw clamp terminals Philips No 2 || 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm || 0.8-1.3 N.m screw clamp terminals pozidriv No 2
Mechanical Durability:
10 Mcycles
Irms Rated Making Capacity:
110 A AC for power circuit conforming to IEC 60947
Signaling Circuit Frequency:
<= 400 Hz
Rated Breaking Capacity:
110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conformin
Protective Treatment:
TC IEC 60068 || TC DIN 50016
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Eu Rohs Directive:
Compliant with Exemptions
[Ie] Rated Operational Current:
20 A (at <60°C) at <= 690 V AC AC-1 for power circuit
Product Or Component Type:
contactor
Rohs Exemption Information:
Yes
Operating Altitude:
6561.68 ft (2000 m) without derating
Heat Dissipation:
3-3 W
Sustainable Offer Status:
Green Premium product
[Ui] Rated Insulation Voltage:
power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA C22.2 No 14
Net Weight:
0.225 kg
Control Circuit Type:
AC 50/60 Hz silent
[Uc] Control Circuit Voltage:
24 V AC 50/60 Hz
Height:
58 mm
Average Impedance:
3 mOhm - Ith 20 A 50 Hz for power circuit
Connections - Terminals:
screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4
Mercury Free:
Yes
Circularity Profile:
ENVEOLI1503003EN
Country of Origin:
France
Maximum Operating Rate:
3600 cyc/h
Inrush Power In Va:
3-3 VA (at 20°C)
Electrical Durability:
0.16 Mcycles 20 A AC-1 <= 690 V
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC <= 400 Hz || Signaling circuit <= 690 V AC <= 400 Hz
Weight:
0.225 kg
Mechanical Robustness:
shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on X axis6 Gn for 11
$132.00