Schneider Electric LGA36400U53X Circuit breaker, PowerPacT L, 400A, 3 pole, 600VAC, 18kA, I-Line, Micrologic 5.3E, 80%, ABC
Schneider Electric
$7,874.00
PowerPacT L-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT L-Frame circuit breakers are available with electronic trip units. All PowerPacT L-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT L circuit breakers are available in 3 and 4-pole unit mount, I-Line, and drawout constructions. This PowerPacT L, 400A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker provides MicroLogic Energy with a 5.3E trip unit and an LSI function. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT L circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Network Frequency:
- 50/60 Hz
- Product Certifications:
- UL || CSA || NOM
- Tightening Torque:
- 50-50 N.m 95-240 mm² (AWG 3/0...500 kcmil)
- Wire Stripping Length:
- 31 mm
- Mounting Mode:
- I-Line bracket)
- Continuous Current Rating:
- 0.8
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Mercury Free:
- Yes
- Control Type:
- toggle
- Environmental Disclosure:
- ENVPEP2206029EN
- Trip Unit Technology:
- electronic, energy, MicroLogic 5.3 E, LSI
- Mounting Height:
- 6 in
- Ip Degree Of Protection:
- front cover IP40
- Length:
- 31 mm
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Product Name:
- PowerPact L
- Mounting Support:
- bracket
- Net Weight:
- 6.2 kg
- Device Application:
- distribution
- Height:
- 340 mm
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz IEC 60947-3
- Protection Technology:
- current limiter
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Rohs Exemption Information:
- Yes
- Range:
- PowerPact
- Communication Interface:
- Modbus || Ethernet
- Pollution Degree:
- 3 IEC 60947-1
- Circuit Breaker Application:
- HACR rated
- Breaking Capacity:
- 65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
- Poles Description:
- 3P
- Phase Connection:
- ABC
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Eu Rohs Directive:
- Compliant with Exemptions
- Pvc Free:
- Yes
- Terminal Identifier:
- AL600LF52K3
- Electrical Connection:
- I-Line connection, line || lugs, load
- Circularity Profile:
- ENVEOLI2206029EN
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Color:
- Black
- Suitability For Isolation:
- yes IEC 60947-2
- Warranty:
- 18 months
- Height:
- 6 in
- Weight:
- 6.2 kg
- Product Or Component Type:
- circuit breaker
- Device Short Name:
- L-Frame
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Breaking Capacity Code:
- G
- Sustainable Offer Status:
- Green Premium product