Schneider Electric

Schneider Electric LGL47120D42 Circuit breaker, PowerPacT L, 1200A, 4 pole, 500VDC, 20kA, lugs, thermal magnetic, 80%

(No reviews yet) Write a Review
SKU:
LGL47120D42
MPN:
LGL47120D42
Condition:
New
Mounting Support:
lug
Device Short Name:
L-Frame
Country of Origin:
United States
Mounting Mode:
unit mount lug)
Product Name:
PowerPact L
Magnetic Tripping Current:
3000-6000 A
Local Signaling:
switched off (OFF) 1 trip indicator green)
Length:
31 mm
Depth:
110 mm
Wire Stripping Length:
31 mm
Suitability For Isolation:
yes IEC 60947-2
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Pvc Free:
Yes
Sustainable Offer Status:
Green Premium product
Tightening Torque:
50-50 N.m 70-240 mm² (AWG 2/0...500 kcmil)
Breaking Capacity:
65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
Protection Technology:
current limiter
Poles Description:
4P
Electrical Connection:
lugs, line || lugs, load
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Net Weight:
6.2 kg
Color:
Black
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Ambient Air Temperature For Storage:
-50-85°C
Ip Degree Of Protection:
front cover IP40
Ambient Air Temperature For Operation:
-25-70°C
Circularity Profile:
ENVEOLI1406010EN
Eu Rohs Directive:
Compliant
Breaking Capacity Code:
G
Mercury Free:
Yes
Range:
PowerPact
Rohs Exemption Information:
Yes
Trip Unit Technology:
thermal-magnetic
Communication Interface:
Modbus || Ethernet
Terminal Identifier:
AL600LS52K4
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Environmental Disclosure:
ENVPEP1406010EN
Pollution Degree:
3 IEC 60947-1
Warranty:
18 months
Line Rated Current:
1200-1200 A
Utilisation Category:
category A
Device Application:
distribution
Weight:
6.2 kg
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Product Or Component Type:
circuit breaker
Control Type:
toggle
$16,500.00

Description

PowerPacT L-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT L-Frame circuit breakers are available with electronic trip units. All PowerPacT L-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT L circuit breakers are available in 3 and 4-pole unit mount, I-Line, and drawout constructions. This PowerPacT L, 1200A, 4 pole, circuit breaker has an interrupting rating of 20kA at 500VDC. This circuit breaker has a fixed long time electronic trip unit. This unit has lugs on both the line and load sides. This circuit breaker has a continuous current rating of 80%. PowerPacT L circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.