Schneider Electric

Schneider Electric LJA34600WU33X Circuit breaker, PowerPacT L, 600A, 3 pole, 480VAC, 65kA, I-Line, MicroLogic 3.3S, 80%, ABC, mission critical

(No reviews yet) Write a Review
SKU:
LJA34600WU33X
MPN:
LJA34600WU33X
Condition:
New
Control Type:
toggle
Mounting Support:
bracket
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Pvc Free:
Yes
Utilisation Category:
category A
Awg Gauge:
2 x AWG 2/0...500 kcmil aluminium/copper
Device Short Name:
L-Frame
Terminal Identifier:
AL600LS52K3
Phase Connection:
ABC
Ambient Air Temperature For Storage:
-50-85°C
Tightening Torque:
50-50 N.m 70-240 mm² (AWG 2/0...500 kcmil) || 50-50 N.m 35-300 mm² (AWG 2...600 kcmil)
Ambient Air Temperature For Operation:
-25-70°C
Trip Unit Name:
MicroLogic 3.3 S
Device Application:
distribution
Circuit Breaker Application:
HACR rated
Continuous Current Rating:
0.8
Length:
31 mm
Rohs Exemption Information:
Yes
Mercury Free:
Yes
Circularity Profile:
ENVEOLI1406010EN
Long Time Pick-Up Adjustment Range:
0.25...1 x In
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Poles Description:
3P
Height:
340 mm
Color:
Black
Network Frequency:
50/60 Hz
Pollution Degree:
3 IEC 60947-1
Breaking Capacity Code:
J
Breaking Capacity:
100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489
Local Signaling:
ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
Country of Origin:
United States
Product Or Component Type:
circuit breaker
Net Weight:
6.2 kg
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Mounting Mode:
I-Line bracket)
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Sustainable Offer Status:
Green Premium product
Suitability For Isolation:
yes IEC 60947-2
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Product Name:
PowerPact L
Communication Interface:
Modbus || Ethernet
Depth:
110 mm
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Trip Unit Technology:
electronic, standard, MicroLogic 3.3 S, LSI
Environmental Disclosure:
ENVPEP1406010EN
Ip Degree Of Protection:
front cover IP40
Weight:
6.2 kg
$13,433.00

Description

PowerPacT L-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT L-Frame circuit breakers are available with electronic trip units. All PowerPacT L-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT L circuit breakers are available in 3 and 4-pole unit mount, I-Line, and drawout constructions. This PowerPacT L, 600A, 3 pole, circuit breaker has an interrupting rating of 65kA at 480VAC. This circuit breaker provides MicroLogic Standard with a 3.3S trip unit and an LSI function. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. This breaker is a PowerPact Mission Critical; it analyzes fault current to make decisions which maximize selectivity with downstream circuit breakers. PowerPacT L circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose