- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Device Application:
- distribution
- [Ics] Rated Service Breaking Capacity:
- 65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Width:
- 140 mm
- Mounting Support:
- bracket
- Breaking Capacity Code:
- J
- Sustainable Offer Status:
- Green Premium product
- Electrical Connection:
- I-Line connection, line || lugs, load
- Circularity Profile:
- ENVEOLI2206029EN
- Trip Unit Technology:
- electronic, ammeter, MicroLogic 5.3 A, LSI
- Ip Degree Of Protection:
- front cover IP40
- Awg Gauge:
- AWG 3/0...500 kcmil aluminium/copper
- Pvc Free:
- Yes
- Network Frequency:
- 50/60 Hz
- Range:
- PowerPact
- Circuit Breaker Application:
- HACR rated
- Product Or Component Type:
- circuit breaker
- Height:
- 340 mm
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz IEC 60947-3
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- Tightening Torque:
- 50-50 N.m 95-240 mm² (AWG 3/0...500 kcmil)
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Continuous Current Rating:
- 0.8
- Suitability For Isolation:
- yes IEC 60947-2
- Pollution Degree:
- 3 IEC 60947-1
- Warranty:
- 18 months
- Device Short Name:
- L-Frame
- Line Rated Current:
- 400-400 A
- Depth:
- 110 mm
- Mounting Height:
- 6 in
- Poles Description:
- 3P
- Net Weight:
- 6.2 kg
- Wire Stripping Length:
- 31 mm
- Rohs Exemption Information:
- Yes
- Communication Interface:
- Modbus || Ethernet
- Color:
- Black
- Product Name:
- PowerPact L
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Environmental Disclosure:
- ENVPEP2206029EN
- Ambient Air Temperature For Operation:
- -2-70 °C
- Control Type:
- toggle
- Local Signalling:
- ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
- Breaking Capacity:
- 100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Phase Connection:
- ABC
- Mounting Mode:
- I-Line bracket)
- Mercury Free:
- Yes
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Eu Rohs Directive:
- Compliant with Exemptions
- Protection Technology:
- current limiter
- Terminal Identifier:
- AL600LF52K3
- Ambient Air Temperature For Storage:
- -50-85 °C
- Trip Unit Name:
- MicroLogic 5.3 A
- Product Certifications:
- UL || CSA || NOM
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Utilisation Category:
- category A