Schneider Electric

Schneider Electric LLA36250CU31X Circuit breaker, PowerPacT L, 250A, 3 pole, 600VAC, 50kA, I-Line, MicroLogic 3.3, 100%, ABC

(No reviews yet) Write a Review
SKU:
LLA36250CU31X
MPN:
LLA36250CU31X
Condition:
New
Mounting Support:
bracket
Height:
340 mm
Control Type:
toggle
Pollution Degree:
3 IEC 60947-1
Line Rated Current:
250-250 A
Circuit Breaker Application:
HACR rated
Depth:
110 mm
Network Frequency:
50/60 Hz
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Length:
31 mm
Product Or Component Type:
circuit breaker
Warranty:
18 months
Breaking Capacity Code:
L
Awg Gauge:
AWG 2...600 kcmil copper || AWG 2...500 kcmil aluminium
Trip Unit Technology:
electronic, standard, MicroLogic 3.3, LI
Trip Unit Name:
MicroLogic 3.3
Environmental Disclosure:
ENVPEP1406010EN
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Ambient Air Temperature For Operation:
-25-70°C
Protection Technology:
current limiter
Country of Origin:
United States
Rohs Exemption Information:
Yes
Eu Rohs Directive:
Compliant
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz IEC 60947-3
Terminal Identifier:
AL400L61K3
Range:
PowerPact
Electrical Connection:
I-Line connection, line || lugs, load
[Ics] Rated Service Breaking Capacity:
125 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 100 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 50 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Continuous Current Rating:
1
Circularity Profile:
ENVEOLI1406010EN
Tightening Torque:
50-50 N.m 35-300 mm² (AWG 2...600 kcmil) || 50-50 N.m 35-240 mm² (AWG 2...500 kcmil)
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Product Certifications:
UL || CSA || NOM
Local Signaling:
ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
Device Application:
distribution
Mercury Free:
Yes
Breaking Capacity:
125 kA 240 V AC 50/60 Hz UL 489 || 100 kA 480 V AC 50/60 Hz UL 489 || 50 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 50 kA 500 V DC UL 489
Phase Connection:
ABC
Mounting Mode:
I-Line bracket)
Sustainable Offer Status:
Green Premium product
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Product Name:
PowerPact L
Wire Stripping Length:
31 mm
Pvc Free:
Yes
Ambient Air Temperature For Storage:
-50-85°C
Mounting Height:
6 in
Color:
Black
$11,899.00

Description

PowerPacT L-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT L-Frame circuit breakers are available with electronic trip units. All PowerPacT L-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT L circuit breakers are available in 3 and 4-pole unit mount, I-Line, and drawout constructions. This PowerPacT L, 250A, 3 pole, circuit breaker has an interrupting rating of 50kA at 600VAC. This circuit breaker provides MicroLogic Standard with a 3.3 trip unit and an LI function. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This circuit breaker has a continuous current rating of 100% with an ABC phase connection. PowerPacT L circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose