Schneider Electric LLA36600U31X Molded Case Circuit Breaker 600V 600A

(No reviews yet) Write a Review
SKU:
LLA36600U31X
UPC:
785901986553
Condition:
New
Sustainable Offer Status:
Green Premium product
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Communication Interface:
Modbus || Ethernet
Warranty:
18 months
Environmental Disclosure:
ENVPEP2206029EN
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Ip Degree Of Protection:
front cover IP40
Device Short Name:
L-Frame
Tightening Torque:
50-50 N.m 70-240 mm² (2 x AWG 2/0...500 kcmil)
Terminal Identifier:
AL600LF52K3
Range:
PowerPact
Rohs Exemption Information:
Yes
Width:
140 mm
Local Signalling:
ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
Ambient Air Temperature For Operation:
-2-70 °C
Line Rated Current:
600-600 A
Electrical Connection:
I-Line connection, line || lugs, load
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Network Frequency:
50/60 Hz
Net Weight:
6.2 kg
Pollution Degree:
3 IEC 60947-1
Mounting Height:
6 in
Breaking Capacity Code:
L
Product Certifications:
UL || CSA || NOM
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz IEC 60947-3
Color:
Black
Awg Gauge:
2 x AWG 2/0...500 kcmil aluminium/copper
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Control Type:
toggle
Poles Description:
3P
Wire Stripping Length:
31 mm
Trip Unit Name:
MicroLogic 3.3
Mounting Support:
bracket
Product Name:
PowerPact L
Depth:
110 mm
Circuit Breaker Application:
HACR rated
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Utilisation Category:
category A
Phase Connection:
ABC
Trip Unit Technology:
electronic, standard, MicroLogic 3.3, LI
[Ics] Rated Service Breaking Capacity:
125 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 100 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 50 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Long Time Pick-Up Adjustment Range:
0.25...1 x In
Mercury Free:
Yes
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Breaking Capacity:
125 kA 240 V AC 50/60 Hz UL 489 || 100 kA 480 V AC 50/60 Hz UL 489 || 50 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 50 kA 500 V DC UL 489
Ambient Air Temperature For Storage:
-50-85 °C
Continuous Current Rating:
0.8
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Circularity Profile:
ENVEOLI2206029EN
Height:
340 mm
Mounting Mode:
I-Line bracket)
Product Or Component Type:
circuit breaker
Suitability For Isolation:
yes IEC 60947-2
Eu Rohs Directive:
Compliant with Exemptions
Pvc Free:
Yes
Device Application:
distribution
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric LLA36600U31X Molded Case Circuit Breaker 600V 600A
  • Schneider Electric LLA36600U31X Molded Case Circuit Breaker 600V 600A
  • Schneider Electric LLA36600U31X Molded Case Circuit Breaker 600V 600A
$12,132.00

Description

PowerPacT L-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT L-Frame circuit breakers are available with electronic trip units. All PowerPacT L-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT L circuit breakers are available in 3 and 4-pole unit mount, I-Line, and drawout constructions. This PowerPacT L, 600A, 3 pole, circuit breaker has an interrupting rating of 50kA at 600VAC. This circuit breaker provides MicroLogic Standard with a 3.3 trip unit and an LI function. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT L circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked. PowerPacT L circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose