Schneider Electric

Schneider Electric LLA36600U33X Circuit breaker, PowerPacT L, 600A, 3 pole, 600VAC, 50kA, I-Line, MicroLogic 3.3S, 80%, ABC

(No reviews yet) Write a Review
SKU:
LLA36600U33X
MPN:
LLA36600U33X
Condition:
New
Mounting Mode:
I-Line bracket)
Suitability For Isolation:
yes IEC 60947-2
Awg Gauge:
2 x AWG 2/0...500 kcmil aluminium/copper
Ambient Air Temperature For Operation:
-25-70°C
Environmental Disclosure:
ENVPEP2206029EN
Continuous Current Rating:
0.8
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Country of Origin:
United States
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz IEC 60947-3
Network Frequency:
50/60 Hz
Line Rated Current:
600-600 A
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Length:
31 mm
Utilisation Category:
category A
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Device Short Name:
L-Frame
Height:
340 mm
Mounting Support:
bracket
Width:
140 mm
[Ics] Rated Service Breaking Capacity:
125 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 100 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 50 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Mounting Height:
6 in
Wire Stripping Length:
31 mm
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Terminal Identifier:
AL600LF52K3
Breaking Capacity Code:
L
Electrical Connection:
I-Line connection, line || lugs, load
Height:
6 in
Product Certifications:
UL || CSA || NOM
Ambient Air Temperature For Storage:
-50-85°C
Product Or Component Type:
circuit breaker
Trip Unit Technology:
electronic, standard, MicroLogic 3.3 S, LSI
Net Weight:
6.2 kg
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Protection Technology:
current limiter
Circuit Breaker Application:
HACR rated
Range:
PowerPact
Tightening Torque:
50-50 N.m 70-240 mm² (2 x AWG 2/0...500 kcmil)
Long Time Pick-Up Adjustment Range:
0.25...1 x In
Circularity Profile:
ENVEOLI2206029EN
Pvc Free:
Yes
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Depth:
110 mm
Eu Rohs Directive:
Compliant with Exemptions
Ip Degree Of Protection:
front cover IP40
Device Application:
distribution
Rohs Exemption Information:
Yes
Control Type:
toggle
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Pollution Degree:
3 IEC 60947-1
$12,725.00

Description

PowerPacT L-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT L-Frame circuit breakers are available with electronic trip units. All PowerPacT L-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT L circuit breakers are available in 3 and 4-pole unit mount, I-Line, and drawout constructions. This PowerPacT L, 600A, 3 pole, circuit breaker has an interrupting rating of 50kA at 600VAC. This circuit breaker provides MicroLogic Standard with a 3.3S trip unit and an LSI function. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT L circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose