Schneider Electric

Schneider Electric LLF37060D33 Circuit breaker, PowerPacT L, 600A, 3 pole, 500VDC, 50kA, busbar, thermal magnetic, 80%

(No reviews yet) Write a Review
SKU:
LLF37060D33
MPN:
LLF37060D33
Condition:
New
Device Application:
distribution
Weight:
6.2 kg
Trip Unit Technology:
thermal-magnetic
Depth:
110 mm
Wire Stripping Length:
31 mm || 61 mm
Control Type:
toggle
Mounting Mode:
unit mount busbar)
Pvc Free:
Yes
Utilisation Category:
category A
Awg Gauge:
2 x AWG 2/0...500 kcmil aluminium/copper
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Circuit Breaker Application:
HACR rated
Sustainable Offer Status:
Green Premium product
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Circularity Profile:
ENVEOLI1406010EN
Product Or Component Type:
circuit breaker
Ambient Air Temperature For Operation:
-25-70°C
Terminal Identifier:
AL600LS52K3
Mounting Support:
busbar
Pollution Degree:
3 IEC 60947-1
Local Signaling:
switched off (OFF) 1 trip indicator green)
Net Weight:
6.2 kg
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Ip Degree Of Protection:
front cover IP40
Communication Interface:
Modbus || Ethernet
Eu Rohs Directive:
Compliant with Exemptions
Magnetic Tripping Current:
1500-3000 A
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Color:
Black
Country of Origin:
United States
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Suitability For Isolation:
yes IEC 60947-2
Rohs Exemption Information:
Yes
Product Certifications:
UL || CSA || NOM
Ambient Air Temperature For Storage:
-50-85°C
Range:
PowerPact
Device Short Name:
L-Frame
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Length:
31 mm
[Ue] Rated Operational Voltage:
500 V DC
Tightening Torque:
50-50 N.m 70-240 mm² (2 x AWG 2/0...500 kcmil)
[Ics] Rated Service Breaking Capacity:
125 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 100 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 50 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Breaking Capacity Code:
L
Breaking Capacity:
125 kA 240 V AC 50/60 Hz UL 489 || 100 kA 480 V AC 50/60 Hz UL 489 || 50 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 50 kA 500 V DC UL 489
Mercury Free:
Yes
Environmental Disclosure:
ENVPEP1406010EN
$10,875.00

Description

PowerPacT L-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT L-Frame circuit breakers are available with electronic trip units. All PowerPacT L-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT L circuit breakers are available in 3 and 4-pole unit mount, I-Line, and drawout constructions. This PowerPacT L, 600A, 3 pole, circuit breaker has an interrupting rating of 50kA at 500VDC. This circuit breaker has a fixed long time electronic trip unit. This unit has a busbar connection. This circuit breaker has a continuous current rating of 80%. PowerPacT L circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.