- Device Application:
- distribution
- Weight:
- 6.2 kg
- Trip Unit Technology:
- thermal-magnetic
- Depth:
- 110 mm
- Wire Stripping Length:
- 31 mm || 61 mm
- Control Type:
- toggle
- Mounting Mode:
- unit mount busbar)
- Pvc Free:
- Yes
- Utilisation Category:
- category A
- Awg Gauge:
- 2 x AWG 2/0...500 kcmil aluminium/copper
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Circuit Breaker Application:
- HACR rated
- Sustainable Offer Status:
- Green Premium product
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Circularity Profile:
- ENVEOLI1406010EN
- Product Or Component Type:
- circuit breaker
- Ambient Air Temperature For Operation:
- -25-70°C
- Terminal Identifier:
- AL600LS52K3
- Mounting Support:
- busbar
- Pollution Degree:
- 3 IEC 60947-1
- Local Signaling:
- switched off (OFF) 1 trip indicator green)
- Net Weight:
- 6.2 kg
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Ip Degree Of Protection:
- front cover IP40
- Communication Interface:
- Modbus || Ethernet
- Eu Rohs Directive:
- Compliant with Exemptions
- Magnetic Tripping Current:
- 1500-3000 A
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Color:
- Black
- Country of Origin:
- United States
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Suitability For Isolation:
- yes IEC 60947-2
- Rohs Exemption Information:
- Yes
- Product Certifications:
- UL || CSA || NOM
- Ambient Air Temperature For Storage:
- -50-85°C
- Range:
- PowerPact
- Device Short Name:
- L-Frame
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Length:
- 31 mm
- [Ue] Rated Operational Voltage:
- 500 V DC
- Tightening Torque:
- 50-50 N.m 70-240 mm² (2 x AWG 2/0...500 kcmil)
- [Ics] Rated Service Breaking Capacity:
- 125 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 100 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 50 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Breaking Capacity Code:
- L
- Breaking Capacity:
- 125 kA 240 V AC 50/60 Hz UL 489 || 100 kA 480 V AC 50/60 Hz UL 489 || 50 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 50 kA 500 V DC UL 489
- Mercury Free:
- Yes
- Environmental Disclosure:
- ENVPEP1406010EN